Provided by: opa-fastfabric_10.10.3.0.11-1ubuntu3_amd64 bug

NAME

       opachassisanalysis

       (Switch) Performs analysis of the chassis.

       The opachassisanalysis tool checks the following for the Intel(R) Omni-Path Fabric Chassis:

       •      Chassis  configuration  (as  reported  by  the  chassis  commands  specified in FF_CHASSIS_CMDS in
              opafastfabric.conf).

       •      Chassis  health  (as  reported  by  the  chassis  command  specified   in   FF_CHASSIS_HEALTH   in
              opafastfabric.conf).

Syntax

       opachassisanalysis [-b|-e] [-s] [-d  dir] [-F  chassisfile]
       [-H 'chassis']

Options

       --help

                 Produces full help text.

       -b

                 Specifies the baseline mode. Default is the compare/check mode.

       -e

                 Evaluates health only. Default is the compare/check mode.

       -s

                 Saves history of failures (errors/differences).

       -d dir

                 Specifies  the top-level directory for saving baseline and history of failed checks. Default is
                 /var/usr/lib/opa/analysis

       -F chassisfile

                 Specifies the file with the chassis in the cluster. Default is /etc/opa/chassis

       -H 'chassis'

                 Specifies the list of chassis on which to execute the command.

Example

       opachassisanalysis

Environment Variables

       The following environment variables are also used by this command:

       CHASSIS

                 List of chassis, used if -F and -H options are not supplied.

       CHASSIS_FILE

                 File containing list of chassis, used if -F and -H options are not supplied.

       FF_ANALYSIS_DIR

                 Top-level directory for baselines and failed health checks.

       FF_CHASSIS_CMDS

                 List of commands to issue during analysis, unused if -e option supplied.

       FF_CHASSIS_HEALTH

                 Single command to issue to check overall health during analysis, unused if -b option supplied.

Details

       Intel recommends that you set up SSH keys for chassis (see opasetupssh ). If SSH keys are not set up, all
       chassis must be configured  with  the  same  admin  password  and  the  password  must  be  kept  in  the
       /etc/opa/opafastfabric.conf configuration file.

       The default set of FF_CHASSIS_CMDS is:

       showInventory fwVersion showNodeDesc timeZoneConf timeDSTConf

       snmpCommunityConf snmpTargetAddr showChassisIpAddr showDefaultRoute

       The  commands specified in FF_CHASSIS_CMDS must be simple commands with no arguments. The output of these
       commands are compared to the baseline using FF_DIFF_CMD. Therefore,  commands  that  include  dynamically
       changing values, such as port packet counters, should not be included in this list.

       FF_CHASSIS_HEALTH  can  specify  one command (with arguments) to be used to check the chassis health. For
       chassis with newer firmware, the hwCheck command is recommended.  For  chassis  with  older  firmware,  a
       benign  command,  such as fruInfo, should be used. The default is hwCheck. Note that only the exit status
       of the FF_CHASSIS_HEALTH command is checked. The output is not  captured  and  compared  in  a  snapshot.
       However, on failure its output is saved to aid diagnosis.

       The  opachassisanalysis tool performs its analysis against one or more chassis in the fabric. As such, it
       permits the chassis to be specified using the -H, -F, CHASSIS, chassis_file  or  opafastfabric.conf.  The
       handling  of  these  options  and  settings  is comparable to opacmdall -C and similar FastFabric Toolset
       commands against a chassis.

       All files generated by opafabricanalysis start with chassis. in the file name.

       The opachassisanalysis tool generates files such as the following within FF_ANALYSIS_DIR. The actual file
       names reflect the individual chassis commands that have been configured through the FF_CHASSIS_HEALTH and
       FF_CHASSIS_CMDS parameters:

       Health Check

       •      latest/chassis.hwCheck Output of hwCheck command for all selected chassis

       Baseline: During a baseline run, the following files are also created in FF_ANALYSIS_DIR /latest.

       •      baseline/chassis.fwVersion Output of fwVersion command for all selected chassis.

       •      baseline/chassis.showChassisIpAddr Output of  the  showChassisIpAddr.  command  for  all  selected
              chassis.

       •      baseline/chassis.showDefaultRoute Output of the showDefaultRoute command for all selected chassis.

       •      baseline/chassis.showNodeDesc Output of the showNodeDesc command for all selected chassis.

       •      baseline/chassis.showInventory Output of the showInventory command for all selected chassis.

       •      baseline/chassis.snmpCommunityConf  Output  of  the  snmpCommunityConf  command  for  all selected
              chassis.

       •      baseline/chassis.snmpTargetAddr Output of the snmpTargetAddr command for all selected chassis.

       •      baseline/chassis.timeDSTConf Output of the timeDSTConf command for all selected chassis.

       •      baseline/chassis.timeZoneConf Output of the timeZoneConf command for all selected chassis.

       Full Analysis: The following .diff files are only created if differences are detected.

       •      latest/chassis.hwCheck Output of the hwCheck command for all selected chassis.

       •      latest/chassis.fwVersion Output of the fwVersion command for all selected chassis.

       •      latest/chassis.fwVersion.diff diff of the baseline and latest fwVersion.

       •      latest/chassis.showChassisIpAddr Output of the showChassisIpAddr command for all selected chassis.

       •      latest/chassis.showChassisIpAddr.diff diff of baseline and latest showChassisIpAddr.

       •      latest/chassis.showDefaultRoute Output of the showDefaultRoute command for all selected chassis.

       •      latest/chassis.showDefaultRoute.diff diff of the baseline and the latest showDefaultRoute.

       •      latest/chassis.showNodeDesc Output of the showNodeDesc command for all selected chassis.

       •      latest/chassis.showNodeDesc.diff diff of the baseline and latest showNodeDesc.

       •      latest/chassis.showInventory Output of the showInventory command for all selected chassis.

       •      latest/chassis.showInventory.diff diff of the baseline and latest showInventory.

       •      latest/chassis.snmpCommunityConf Output of the snmpCommunityConf command for all selected chassis.

       •      latest/chassis.snmpCommunityConf.diff diff of the baseline and latest snmpCommunityConf.

       •      latest/chassis.snmpTargetAddr Output of the snmpTargetAddr command for all selected chassis.

       •      latest/chassis.snmpTargetAddr.diff diff of the baseline and latest snmpTargetAddr.

       •      latest/chassis.timeDSTConf Output of the timeDSTConf command for all selected chassis.

       •      latest/chassis.timeDSTConf.diff diff of the baseline and latest timeDSTConf.

       •      latest/chassis.timeZoneConf Output of the timeZoneConf command for all selected chassis.

       •      latest/chassis.timeZoneConf.diff diff of the baseline and latest timeZonfConf.

       If the -s option is used and failures are detected, files related to the  checks  that  failed  are  also
       copied to a time-stamped directory name under FF_ANALYSIS_DIR.

Chassis Items Checked Against the Baseline

       Based upon showInventory :

       •      Addition/removal  of  Chassis FRUsReplacement is only checked for FRUs that showInventory displays
              the serial number.

       •      Removal of redundant FRUs (spines, power supply, fan)

       Based upon fwVersion:

       •      Changes to primary or alternate FW versions installed in cards in chassis.

       Based upon showNodeDesc:

       •      Changes to configured node description for chassis. Note  changes  detected  here  would  also  be
              detected in fabric level analysis.

       Based upon timeZoneConf and timeDSTConf:

       •      Changes to the chassis time zone and daylight savings time configuration.

       Based upon snmpCommunityConf and snmpTargetAddr:

       •      Changes to SNMP persistent configuration within the chassis.

       The following Chassis items are not checked against baseline:

       •      Changes  to  the  chassis  configuration  on  the  management LAN (for example, showChassisIpAddr,
              showDefaultRoute). Such changes typically result in the chassis not responding on the LAN  at  the
              expected address that is detected by failures that perform other chassis checks.

Chassis Items Also Checked During Health Check

       Based upon hwCheck:

       •      Overall health of FRUs in chassis:

       •      Status of Fans in chassis

       •      Status of Power Supplies in chassis

       •      Temp/Voltage for each card

       •      Presence of adequate power/cooling of FRUs

       •      Presence of N+1 power/cooling of FRUs

       •      Presence of Redundant AC input

Copyright(C) 2015-2019                          Intel Corporation                          opachassisanalysis(8)