Provided by: ganeti-3.1_3.1.0~rc2-3_all bug

Name

       ganeti-noded - Ganeti node daemon

Synopsis

       ganeti-noded [-f] [-d] [-p PORT] [-b ADDRESS] [-i INTERFACE]
       [--max-clients CLIENTS] [--no-mlock] [--syslog] [--no-ssl]
       [-K SSL_KEY_FILE] [-C SSL_CERT_FILE]

DESCRIPTION

       The ganeti-noded is the daemon which is responsible for the node functions in the Ganeti system.

       By default, in order to be able to support features such as node powercycling even on systems with a very
       damaged  root  disk, ganeti-noded locks itself in RAM using mlockall(2).  You can disable this feature by
       passing in the --no-mlock to the daemon.

       For testing purposes, you can give the -f option and the program won't detach from the running terminal.

       Debug-level message can be activated by giving the -d option.

       Logging to syslog, rather than its own log file, can be enabled by passing in the --syslog option.

       The ganeti-noded daemon listens to port 1811 TCP, on  all  interfaces,  by  default.   The  port  can  be
       overridden by an entry in the services database (usually /etc/services) or by passing the -p option.  The
       -b  option  can  be  used  to specify the address to bind to (defaults to 0.0.0.0); alternatively, the -i
       option can be used to specify the interface to bind do.

       The maximum number of simultaneous client connections may be configured with  the  --max-clients  option.
       This  defaults  to 20.  Connections above this count are accepted, but no responses are sent until enough
       connections are closed.

       Ganeti noded communication is protected via SSL, with a key generated at cluster init time.  This can  be
       disabled  with  the --no-ssl option, or a different SSL key and certificate can be specified using the -K
       and -C options.

   ROLE
       The role of the node daemon is to do almost all the actions that change the state of  the  node.   Things
       like  creating  disks  for instances, activating disks, starting/stopping instance and so on are done via
       the node daemon.

       Also, in some cases the startup/shutdown of the master daemon are done  via  the  node  daemon,  and  the
       cluster IP address is also added/removed to the master node via it.

       If  the  node  daemon is stopped, the instances are not affected, but the master won't be able to talk to
       that node.

   COMMUNICATION PROTOCOL
       Currently the master-node RPC is done using a simple RPC protocol built using JSON over HTTP(S).

REPORTING BUGS

       Report bugs to the project's issue tracker or contact the developers using the Ganeti mailing list.

SEE ALSO

       Ganeti overview and  specifications:  ganeti(7)  (general  overview),  ganeti-os-interface(7)  (guest  OS
       definitions), ganeti-extstorage-interface(7) (external storage providers).

       Ganeti  commands:  gnt-cluster(8) (cluster-wide commands), gnt-job(8) (job-related commands), gnt-node(8)
       (node-related  commands),  gnt-instance(8)  (instance   commands),   gnt-os(8)   (guest   OS   commands),
       gnt-storage(8)   (storage   commands),   gnt-group(8)  (node  group  commands),  gnt-backup(8)  (instance
       import/export commands), gnt-debug(8) (debug commands).

       Ganeti daemons: ganeti-watcher(8) (automatic instance restarter), ganeti-cleaner(8) (job queue  cleaner),
       ganeti-noded(8) (node daemon), ganeti-rapi(8) (remote API daemon).

       Ganeti  htools: htools(1) (generic binary), hbal(1) (cluster balancer), hspace(1) (capacity calculation),
       hail(1) (IAllocator plugin), hscan(1) (data gatherer from remote clusters), hinfo(1) (cluster information
       printer), mon-collector(7) (data collectors interface).

COPYRIGHT

       Copyright (C) 2006-2015 Google Inc.  All rights reserved.

       Redistribution and use in source and binary forms, with or without modification, are  permitted  provided
       that the following conditions are met:

       1.   Redistributions  of  source code must retain the above copyright notice, this list of conditions and
       the following disclaimer.

       2.  Redistributions in binary form must reproduce the above copyright notice, this list of conditions and
       the following disclaimer in the documentation and/or other materials provided with the distribution.

       THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY  EXPRESS  OR  IMPLIED
       WARRANTIES,  INCLUDING,  BUT  NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
       PARTICULAR PURPOSE ARE DISCLAIMED.  IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE  FOR
       ANY  DIRECT,  INDIRECT,  INCIDENTAL,  SPECIAL,  EXEMPLARY,  OR  CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
       LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF  USE,  DATA,  OR  PROFITS;  OR  BUSINESS
       INTERRUPTION)  HOWEVER  CAUSED  AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR
       TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE  OF  THIS  SOFTWARE,  EVEN  IF
       ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

Ganeti                                                                                           ganeti-noded(8)