NAME

       ipmi-config - IPMI configuration file details

DESCRIPTION

       Before many IPMI tools can be used over a network, a machine's Baseboard Management Controller (BMC) must
       be  configured.  The  configuration can be quite daunting for those who do not know much about IPMI. This
       manpage hopes to provide enough information on BMC configuration so that you can configure  the  BMC  for
       your system. When appropriate, typical BMC configurations will be suggested.

       The  following is an example configuration file partially generated by running the --checkout option with
       the ipmi-config(8) command. This configuration comes from the core category of configuration values  (the
       default).  This  example configuration should be sufficient for most users after the appropriate local IP
       and MAC addresses are input. Following this example, separate sections of this manpage will  discuss  the
       different  sections  of  the  configuration  file  in more detail with explanations of how the BMC can be
       configured for different environments.

       Note that many options may or may not be available on your particular machine. For example,  Serial-Over-
       Lan  (SOL) is available only on IPMI 2.0 machines. Therefore, if you are looking to configure an IPMI 1.5
       machine, many of the SOL or IPMI 2.0 related options will  be  be  unavailable  to  you.  The  number  of
       configurable users may also vary for your particular machine.

       The  below configuration file and most of this manpage assume the user is interested in configuring a BMC
       for use with IPMI over LAN.  Various configuration options from ipmi-config(8)  have  been  left  out  or
       skipped  because  it is considered unnecessary.  Future versions of this manpage will try to include more
       information.

            Section User1
             ## Give username
             ## Username NULL
             ## Give password or leave it blank to clear password
             Password mypassword
             ## Possible values: Yes/No or blank to not set
             Enable_User Yes
             ## Possible values: Yes/No
             Lan_Enable_Ipmi_Msgs Yes
             ## Possible values: Callback/User/Operator/Administrator/OEM_Proprietary/No_Access
             Lan_Privilege_Limit Administrator
               ## Possible values: 0-17, 0 is unlimited; May be reset to 0 if not specified
               ## Lan_Session_Limit
             ## Possible values: Yes/No
             SOL_Payload_Access Yes
            EndSection
            Section User2
             ## Give username
             Username user2
             ## Give password or leave it blank to clear password
             Password userpass
             ## Possible values: Yes/No or blank to not set
             Enable_User No
             ## Possible values: Yes/No
             Lan_Enable_Ipmi_Msgs No
             ## Possible values: Callback/User/Operator/Administrator/OEM_Proprietary/No_Access
             Lan_Privilege_Limit No_Access
               ## Possible values: 0-17, 0 is unlimited; May be reset to 0 if not specified
               ## Lan_Session_Limit
               ## Possible values: Yes/No
               SOL_Payload_Access No
            EndSection
            Section Lan_Channel
             ## Possible values: Disabled/Pre_Boot_Only/Always_Available/Shared
             Volatile_Access_Mode Always_Available
             ## Possible values: Yes/No
             Volatile_Enable_User_Level_Auth Yes
             ## Possible values: Yes/No
             Volatile_Enable_Per_Message_Auth Yes
             ## Possible values: Yes/No
             Volatile_Enable_Pef_Alerting No
             ## Possible values: Callback/User/Operator/Administrator/OEM_Proprietary/No_Access
             Volatile_Channel_Privilege_Limit Administrator
             ## Possible values: Disabled/Pre_Boot_Only/Always_Available/Shared
             Non_Volatile_Access_Mode Always_Available
             ## Possible values: Yes/No
             Non_Volatile_Enable_User_Level_Auth Yes
             ## Possible values: Yes/No
             Non_Volatile_Enable_Per_Message_Auth Yes
             ## Possible values: Yes/No
             Non_Volatile_Enable_Pef_Alerting No
             ## Possible values: Callback/User/Operator/Administrator/OEM_Proprietary/No_Access
             Non_Volatile_Channel_Privilege_Limit Administrator
            EndSection
            Section Lan_Conf
             ## Possible values: Unspecified/Static/Use_DHCP/Use_BIOS/Use_Others
             Ip_Address_Source Static
             ## Give valid IP Address
             Ip_Address 192.168.1.100
             ## Give valid MAC Address
             Mac_Address 00:0E:0E:FF:AA:12
             ## Give valid Subnet mask
             Subnet_Mask 255.255.255.0
             ## Give valid IP Address
             Default_Gateway_Ip_Address 192.168.1.1
             ## Give valid MAC Address
             Default_Gateway_Mac_Address 00:0E:0E:FF:AA:18
             ## Give valid IP Address
             Backup_Gateway_Ip_Address 192.168.1.2
             ## Give valid MAC Address
             Backup_Gateway_Mac_Address 00:0E:0E:FF:AA:15
            EndSection
            Section Lan_Conf_Auth
             ## Possible values: Yes/No
             Callback_Enable_Auth_Type_None No
             ## Possible values: Yes/No
             Callback_Enable_Auth_Type_Md2 No
             ## Possible values: Yes/No
             Callback_Enable_Auth_Type_Md5 No
             ## Possible values: Yes/No
             Callback_Enable_Auth_Type_Straight_Password No
             ## Possible values: Yes/No
             Callback_Enable_Auth_Type_Oem_Proprietary No
             ## Possible values: Yes/No
             User_Enable_Auth_Type_None No
             ## Possible values: Yes/No
             User_Enable_Auth_Type_Md2 Yes
             ## Possible values: Yes/No
             User_Enable_Auth_Type_Md5 Yes
             ## Possible values: Yes/No
             User_Enable_Auth_Type_Straight_Password No
             ## Possible values: Yes/No
             User_Enable_Auth_Type_Oem_Proprietary No
             ## Possible values: Yes/No
             Operator_Enable_Auth_Type_None No
             ## Possible values: Yes/No
             Operator_Enable_Auth_Type_Md2 Yes
             ## Possible values: Yes/No
             Operator_Enable_Auth_Type_Md5 Yes
             ## Possible values: Yes/No
             Operator_Enable_Auth_Type_Straight_Password No
             ## Possible values: Yes/No
             Operator_Enable_Auth_Type_Oem_Proprietary No
             ## Possible values: Yes/No
             Admin_Enable_Auth_Type_None No
             ## Possible values: Yes/No
             Admin_Enable_Auth_Type_Md2 Yes
             ## Possible values: Yes/No
             Admin_Enable_Auth_Type_Md5 Yes
             ## Possible values: Yes/No
             Admin_Enable_Auth_Type_Straight_Password No
             ## Possible values: Yes/No
             Admin_Enable_Auth_Type_Oem_Proprietary No
             ## Possible values: Yes/No
             Oem_Enable_Auth_Type_None No
             ## Possible values: Yes/No
             Oem_Enable_Auth_Type_Md2 No
             ## Possible values: Yes/No
             Oem_Enable_Auth_Type_Md5 No
             ## Possible values: Yes/No
             Oem_Enable_Auth_Type_Straight_Password No
             ## Possible values: Yes/No
             Oem_Enable_Auth_Type_Oem_Proprietary No
            EndSection
            Section Lan_Conf_Security_Keys
               ## Give string or blank to clear. Max 20 chars
               K_G
            EndSection
            Section Lan_Conf_Misc
             ## Possible values: Yes/No
             Enable_Gratuitous_Arps Yes
             ## Possible values: Yes/No
             Enable_Arp_Response No
             ## Give valid number. Intervals are 500 ms.
             Gratuitous_Arp_Interval 4
            EndSection
            Section Rmcpplus_Conf_Privilege
             ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
             Maximum_Privilege_Cipher_Suite_Id_0 Unused
             ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
             Maximum_Privilege_Cipher_Suite_Id_1 Unused
             ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
             Maximum_Privilege_Cipher_Suite_Id_2 Unused
             ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
             Maximum_Privilege_Cipher_Suite_Id_3 Administrator
             ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
             Maximum_Privilege_Cipher_Suite_Id_4 Administrator
             ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
             Maximum_Privilege_Cipher_Suite_Id_5 Administrator
             ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
             Maximum_Privilege_Cipher_Suite_Id_6 Unused
             ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
             Maximum_Privilege_Cipher_Suite_Id_7 Unused
             ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
             Maximum_Privilege_Cipher_Suite_Id_8 Administrator
             ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
             Maximum_Privilege_Cipher_Suite_Id_9 Administrator
             ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
             Maximum_Privilege_Cipher_Suite_Id_10 Administrator
             ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
             Maximum_Privilege_Cipher_Suite_Id_11 Unused
             ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
             Maximum_Privilege_Cipher_Suite_Id_12 Administrator
             ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
             Maximum_Privilege_Cipher_Suite_Id_13 Administrator
             ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
             Maximum_Privilege_Cipher_Suite_Id_14 Administrator
            EndSection
            Section SOL_Conf
             ## Possible values: Yes/No
             Enable_SOL Yes
             ## Possible values: Callback/User/Operator/Administrator/OEM_Proprietary
             SOL_Privilege_Level Administrator
             ## Possible values: Yes/No
             Force_SOL_Payload_Authentication Yes
             ## Possible values: Yes/No
             Force_SOL_Payload_Encryption Yes
             ## Give a valid integer. Each unit is 5ms
             Character_Accumulate_Interval 50
             ## Give a valid number
             Character_Send_Threshold 100
             ## Give a valid integer
             SOL_Retry_Count 5
             ## Give a valid integer. Interval unit is 10ms
             SOL_Retry_Interval 50
             ## Possible values: Serial/9600/19200/38400/57600/115200
             Non_Volatile_Bit_Rate 115200
             ## Possible values: Serial/9600/19200/38400/57600/115200
             Volatile_Bit_Rate 115200
            EndSection

Section User1, User2, ...

       The User sections of the BMC configuration  file  are  for  username  configuration  for  IPMI  over  LAN
       communication.  The  number of users available to be configured on your system will vary by manufacturer.
       With the exception of the Username for User1, all sections are identical.

       The username(s) you wish to configure the BMC with are defined with Username. The  first  username  under
       Section User1 is typically the NULL username and cannot be modified. The password for the username can be
       specified  with  Password.  It  can be left empty to define a NULL password. Each user you wish to enable
       must be enabled through the Enable_User configuration option. It is recommended that all  usernames  have
       non-NULL passwords or be disabled for security reasons.

       Lan_Enable_Ipmi_Msgs  is  used to enable or disable IPMI over LAN access for the user. This should be set
       to "Yes" to allow IPMI over LAN tools to work.

       Lan_Privilege_Limit specifies the maximum privilege level limit  the  user  is  allowed.  Different  IPMI
       commands  have  different  privilege restrictions. For example, determining the power status of a machine
       only requires the "User" privilege level. However,  power  cycling  requires  the  "Operator"  privilege.
       Typically, you will want to assign atleast one user with a privilege limit of "Administrator" so that all
       system functions are available to atleast one user via IPMI over LAN.

       Lan_Session_Limit  specifies  the  number  of simultaneous IPMI sessions allowed for the user. Most users
       will wish to set this to "0" to allow unlimited simultaneous IPMI  sessions.  This  field  is  considered
       optional by IPMI standards, and may result in errors when attempting to configure it to a non-zero value.
       If errors to occur, setting the value back to 0 should resolve problems.

       SOL_Payload_Access  specifies if a particular user is allowed to connect with Serial-Over-LAN (SOL). This
       should be set to "Yes" to allow this username to use SOL.

       The example configuration above disables "User2" but enables the default "NULL"  (i.e.  anonymous)  user.
       Many  IPMI  tools  (both open-source and vendor) do not allow the user to input a username and assume the
       NULL username by default. If the tools you are interested in using allow usernames to be input,  then  it
       is  recommended that one of the non-NULL usernames be enabled and the NULL username disabled for security
       reasons. It is recommended that you disable the NULL  username  in  section  User1,  so  that  users  are
       required to specify a username for IPMI over LAN communication.

       Some  motherboards  may  require a Username to be configured prior to other fields being read/written. If
       this is the case, those fields will be set to <username-not-set-yet>.

Section Lan_Channel

       The Lan_Channel section configures a variety of IPMI over LAN configuration parameters. Both Volatile and
       Non_Volatile configurations can be set. Volatile configurations are immediately configured onto  the  BMC
       and  will  have  immediate effect on the system. Non_Volatile configurations are only available after the
       next system reset. Generally, both the Volatile and Non_Volatile should be configured identically.

       The Access_Mode parameter configures the availability of IPMI over LAN  on  the  system.  Typically  this
       should be set to "Always_Available" to enable IPMI over LAN.

       The  Privilege_Limit sets the maximum privilege any user of the system can have when performing IPMI over
       LAN. This should be set to the maximum privilege level configured to a username. Typically,  this  should
       be set to "Administrator".

       Typically  User_Level_Auth and Per_Message_Auth should be set to "Yes" for additional security. Disabling
       User_Level_Auth allows "User" privileged IPMI commands to be executed without  authentication.  Disabling
       Per_Message_Auth allows fewer individual IPMI messages to require authentication.

Section Lan_Conf

       Those  familiar with setting up networks should find most of the fields in this section self explanatory.
       The  example  BMC  configuration  above  illustrates  the  setup  of  a  static  IP  address.  The  field
       IP_Address_Source  is  configured with "Static". The IP address, subnet mask, and gateway IP addresses of
       the machine are respectively configured with the IP_Address, Subnet_Mask, Default_Gateway_Ip_Address, and
       Backup_Gateway_Ip_Address fields. The respective MAC addresses for the IP addresses are configured  under
       Mac_Address, Default_Gateway_Mac_Address, and Backup_Gateway_Mac_Address.

       It is not required to setup the BMC IP_Address to be the same P_Address used by your operating system for
       that network interface. However, if you choose to use a different address, an alternate ARP configuration
       may need to be setup.

       To  instead setup your BMC network information via DHCP, the field IP_Address_Source should be configured
       with "Use_DHCP".

       It  is  recommended  that  static  IP  addresses  be  configured  for  address  resolution  reasons.  See
       Lan_Conf_Misc below for a more detailed explanation.

Section Lan_Conf_Auth

       This  section  determines  what  types  of  password  authentication  mechanisms are allowed for users at
       different privilege levels under the IPMI 1.5 protocol. The currently  supported  authentication  methods
       for  IPMI  1.5  are  None  (no  username/password required), Straight_Password (passwords are sent in the
       clear), MD2 (passwords are MD2 hashed), and MD5 (passwords  are  MD5  hashed).   Different  usernames  at
       different  privilege  levels  may  be allowed to authenticate differently through this configuration. For
       example, a username with "User" privileges may be allowed to authenticate with a straight password, but a
       username with "Administrator" privileges may be allowed only authenticate with MD5.

       The above example configuration supports MD2  and  MD5  authentication  for  all  users  at  the  "User",
       "Operator",  and  "Administrator"  privilege levels. All authentication mechanisms have been disabled for
       the "Callback" privilege level.

       Generally speaking, you do not want to allow any user to authenticate with None or Straight_Password  for
       security  reasons.  MD2 and MD5 are digital signature algorithms that can minimally encrypt passwords. If
       you have chosen to support the NULL username (enabled  User1)  and  NULL  passwords  (NULL  password  for
       User1), you will have to enable the None authentication fields above to allow users to connect via None.

Section Lan_Conf_Security_Keys

       This  section supports configuration of the IPMI 2.0 (including Serial-over-LAN) K_g key. If your machine
       does not support IPMI 2.0, this field will not be configurable.

       The key is used for two-key authentication in IPMI 2.0. In most tools, when doing IPMI 2.0, the  K_g  can
       be optionally specified. It is not required for IPMI 2.0 operation.

       In the above example, we have elected to leave this field blank so the K_g key is not used.

Section Lan_Conf_Misc

       This  section  lists  miscellaneous  IPMI  over  LAN  configuration  options.   These  are  optional IPMI
       configuration options that are not implemented on all BMCs.

       Normally, a client cannot resolve the ethernet MAC address without the remote operating  system  running.
       However,  IPMI  over  LAN  would  not work when a machine is powered off or if the IP address used by the
       operating system for that network interface differs from the BMC IP Address. One way to work around  this
       is  through  gratuitous  ARPs.   Gratuitous  ARPs  are  ARP  packets generated by the BMC and sent out to
       advertise the BMC's IP and MAC address.  Other machines on the network  can  store  this  information  in
       their  local  ARP cache for later IP/hostname resolution. This would allow IPMI over LAN to work when the
       remote machine is powered off. The Enable_Gratuitous_Arps option allows you to  enable  or  disable  this
       feature.  The  Gratuitous_Arp_Interval  option  allows you to configure the frequency at which gratuitous
       ARPs are sent onto the network.

       Instead of gratuitous ARPs some BMCs are able to respond to ARP  requests,  even  when  powered  off.  If
       offerred, this feature can be enabled through the Enable_Arp_Response option.

       Generally  speaking, turning on gratuitous ARPs is acceptable.  However, it will increase traffic on your
       network.  If you are using IPMI on a large cluster, the gratuitous ARPs may easily  flood  your  network.
       They  should be tuned to occur less frequently or disabled. If disabled, the remote machine's MAC address
       should be permanently stored in the local ARP cache through arp(8).

       See bmc-watchdog(8) for a method which allows gratuitous ARPs to be disabled when the operating system is
       running, but enabled when the system is down.

Section Rmcpplus_Conf_Privilege

       This section supports configuration of the IPMI 2.0 (including Serial-over-LAN) cipher suite IDs. If your
       machine does not support IPMI 2.0, the fields will not be configurable.

       Each cipher suite ID describes a combination of an authentication  algorithm,  integrity  algorithm,  and
       encryption algorithm for IPMI 2.0.  The authentication algorithm is used for user authentication with the
       BMC.  The  integrity  algorithm  is  used  for generating signatures on IPMI packets. The confidentiality
       algorithm is used for encrypting data. The configuration in this section enables certain cipher suite IDs
       to be enabled or disabled, and the maximum privilege level a username can authenticate with.

       The following table shows the cipher suite ID to algorithms mapping:

       0 - Authentication Algorithm = None; Integrity Algorithm = None; Confidentiality Algorithm = None

       1 - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm = None; Confidentiality Algorithm = None

       2 - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm = HMAC-SHA1-96; Confidentiality Algorithm =
       None

       3 - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm = HMAC-SHA1-96; Confidentiality Algorithm =
       AES-CBC-128

       4 - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm = HMAC-SHA1-96; Confidentiality Algorithm =
       xRC4-128

       5 - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm = HMAC-SHA1-96; Confidentiality Algorithm =
       xRC4-40

       6 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = None; Confidentiality Algorithm = None

       7 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = HMAC-MD5-128; Confidentiality Algorithm  =
       None

       8  - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = HMAC-MD5-128; Confidentiality Algorithm =
       AES-CBC-128

       9 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = HMAC-MD5-128; Confidentiality Algorithm  =
       xRC4-128

       10 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = HMAC-MD5-128; Confidentiality Algorithm =
       xRC4-40

       11 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = MD5-128; Confidentiality Algorithm = None

       12 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = MD5-128; Confidentiality Algorithm = AES-
       CBC-128

       13  -  Authentication  Algorithm  =  HMAC-MD5; Integrity Algorithm = MD5-128; Confidentiality Algorithm =
       xRC4-128

       14 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm  =  MD5-128;  Confidentiality  Algorithm  =
       xRC4-40

       Generally  speaking, HMAC-SHA1 based algorithms are stronger than HMAC-MD5, which are better than MD5-128
       algorithms. AES-CBC-128 confidentiality algorithms are  stronger  than  xRC4-128  algorithms,  which  are
       better than xRC4-40 algorithms. Cipher suite ID 3 is therefore typically considered the most secure. Some
       users may wish to set cipher suite ID 3 to a privilege level and disable all remaining cipher suite IDs.

       The  above  example  configuration  has decided to allow any user with "Administrator" privileges use any
       Cipher Suite algorithm suite which requires an authentication, integrity, and confidentiality  algorithm.
       Typically,  the  maximum  privilege  level  configured to a username should be set for atleast one cipher
       suite ID. Typically, this is the "Administrator" privilege.

       A number of cipher suite IDs are optionally implemented, so the available cipher suite IDs available your
       system may vary.

Section SOL_Conf

       This section is for setting up Serial-Over-Lan (SOL) and will only  be  available  for  configuration  on
       those  machines.  SOL  can be enabled with the Enable_SOL field. The minimum privilege level required for
       connecting with SOL is specified by SOL_Privilege_Level.  This should be set  to  the  maximum  privilege
       level  configured  to  a username that has SOL enabled. Typically, this is the "Administrator" privilege.
       Authentication and Encryption can be forced or not using the fields Force_SOL_Payload_Authentication  and
       Force_SOL_Payload_Encryption  respectively.  It  is  recommended  that  these  be set on. However, forced
       authentication and/or encryption support depend on the cipher suite IDs supported.

       The Character_Accumulate_Interval, Character_Send_Threshold , SOL_Retry_Count  and  ,  SOL_Retry_Interval
       options  are  used to set SOL character output speeds. Character_Accumulate_Interval determines how often
       serial data should be regularly sent and Character_Send_Threshold indicates the character count  that  if
       passed,  will  force  serial  data  to  be sent. SOL_Retry_Count indicates how many times packets must be
       retransmitted if acknowledgements are not received. SOL_Retry_Interval indicates  the  timeout  interval.
       Generally,  the  manufacturer recommended numbers will be sufficient. However, you may wish to experiment
       with these values for faster SOL throughput.

       The Non_Volatile_Bit_Rate and Volatile_Bit_Rate determine the baudrate the BMC should  use.  This  should
       match the baudrate set in the BIOS and operating system, such as agetty(8).  Generally speaking, both the
       Volatile and Non_Volatile options should be set identically.

       In  addition  to  enabling  SOL in this section, individual users most also be capable of connecting with
       SOL. See the section Section User1, User2, ...  above for details.

REPORTING BUGS

       Report bugs to <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

SEE ALSO

       freeipmi(7), bmc-watchdog(8), ipmi-config(8), agetty(8)

       http://www.gnu.org/software/freeipmi/