NAME

       vfs11_vfd - HAL non-realtime component for Toshiba-Schneider VF-S11 Variable Frequency Drives

SYNOPSIS

       vfs11_vfd [OPTIONS]

DESCRIPTION

       This  manual  page  explains  the vfs11_vfd component. This component reads and writes to the vfs11 via a
       Modbus connection.

       vfs11_vfd is for use with LinuxCNC.

OPTIONS

       -n --name <halname>
              set the HAL component name

       -d --debug
              Turn on debugging messages. Also toggled by sending a USR1 signal to the vfs11_vfd process.

       -m --modbus-debug
              Turn on Modbus debugging messages. This will cause all Modbus messages to be printed in hex on the
              terminal.  Also toggled by sending a USR2 signal to the vfs11_vfd process.

       -I --ini <INI file>
              takes configuration from this INI file.  Defaults to environment variable INI_FILE_NAME.

       -S --section <section name>
              take configuration from this section in the INI file. Defaults to 'VFS11'.

       -r --report-device
              report device propertiers on console at startup

PINS

       <name>.acceleration-pattern (bit, in)
              when true, set acceleration  and  deceleration  times  as  defined  in  registers  F500  and  F501
              respectively.  Used in PID loops to choose shorter ramp times to avoid oscillation.

       <name>.alarm-code (s32, out)
              non-zero  if  drive  is  in  alarmed state. Bitmap describing alarm information (see register FC91
              description).  Use err-reset (see below) to clear the alarm.

       <name>.at-speed (bit, out)
              when drive is at commanded speed (see speed-tolerance below)

       <name>.current-load-percentage (float, out)
              reported from the VFD

       <name>.dc-brake  (bit, in)
              engage the DC brake. Also turns off spindle-on.

       <name>.enable (bit, in)
              enable the VFD.  If false, all operating parameters are still read but  control  is  released  and
              panel control is enabled (subject to VFD setup).

       <name>.err-reset (bit, in)
              reset  errors (alarms a.k.a Trip and e-stop status).  Resetting the VFD may cause a 2-second delay
              until it's rebooted and Modbus is up again.

       <name>.estop (bit, in)
              put the VFD into emergency-stopped status. No operation possible until cleared with  err-reset  or
              powercycling.

       <name>.frequency-command (float, out)
              current target frequency in Hz as set through speed-command (which is in RPM), from the VFD

       <name>.frequency-out (float, out)
              current output frequency of the VFD

       <name>.inverter-load-percentage (float, out)
              current load report from VFD

       <name>.is-e-stopped (bit, out)
              the  VFD is in emergency stop status (blinking "E" on panel).  Use err-reset to reboot the VFD and
              clear the e-stop status.

       <name>.is-stopped (bit, out)
              true when the VFD reports 0 Hz output

       <name>.jog-mode (bit, in)
              1 for ON and 0 for OFF, enables the VF-S11 'jog mode'.  Speed control is disabled, and the  output
              frequency  is  determined  by  register  F262  (preset to 5 Hz).  This might be useful for spindle
              orientation.

       <name>.max-rpm (float, R)
              actual RPM limit based on maximum frequency the VFD may generate, and the motors nameplate values.
              For instance, if nameplate-HZ is 50, and nameplate-RPM_ is 1410, but the VFD may  generate  up  to
              80Hz,  then  max-rpm  would read as 2256 (80*1410/50). The frequency limit is read from the VFD at
              startup.  To increase the upper frequency limit, the UL and FH parameters must be changed  on  the
              panel.  See the VF-S11 manual for instructions how to set the maximum frequency.

       <name>.modbus-ok (bit, out)
              true  when  the  Modbus  session is successfully established and the last 10 transactions returned
              without error.

       <name>.motor-RPM (float, out)
              estimated current RPM value, from the VFD

       <name>.output-current-percentage (float, out)
              from the VFD

       <name>.output-voltage-percentage (float, out)
              from the VFD

       <name>.output-voltage (float, out)
              from the VFD

       <name>.speed-command (float, in)
              speed sent to VFD in RPM.  It is an error to send a speed faster than the Motor Max RPM as set  in
              the VFD

       <name>.spindle-fwd (bit, in)
              1 for FWD and 0 for REV, sent to VFD

       <name>.spindle-on (bit, in)
              1 for ON and 0 for OFF sent to VFD, only on when running

       <name>.spindle-rev (bit, in)
              1 for ON and 0 for OFF, only on when running

       <name>.max-speed (bit, in)
              ignore  the  loop-time  parameter  and  run  Modbus at maximum speed, at the expense of higher CPU
              usage.  Suggested use during spindle positioning.

       <name>.status (s32, out)
              Drive Status of the VFD (see  the  TOSVERT  VF-S11  Communications  Function  Instruction  Manual,
              register FD01). A bitmap.

       <name>.trip-code (s32, out)
              trip code if VF-S11 is in tripped state.

       <name>.error-count (s32, RW)
              total number of transactions returning a Modbus error

PARAMETERS

       <name>.frequency-limit (float, RO)
              upper limit read from VFD setup.

       <name>.loop-time (float, RW)
              how often the Modbus is polled (default interval 0.1 seconds)

       <name>.nameplate-HZ (float, RW)
              Nameplate  Hz  of  motor  (default  50).   Used  to  calculate  target  frequency  (together  with
              nameplate-RPM ) for a target RPM value as given by speed-command.

       <name>.nameplate-RPM (float, RW)
              Nameplate RPM of motor (default 1410)

       <name>.rpm-limit (float, RW)
              do-not-exceed soft limit for motor RPM (defaults to nameplate-RPM ).

       <name>.tolerance (float, RW)
              speed tolerance (default 0.01) for determining whether spindle is at speed (0.01  meaning:  output
              frequency is within 1% of target frequency)

USAGE

       The  vfs11_vfd  driver  takes  precedence  over  panel  control  while  it  is enabled (see .enable pin),
       effectively disabling the panel. Clearing the .enable pin re-enableds the panel. Pins and parameters  can
       still  be set, but will not be written to the VFD untile the .enable pin is set. Operating parameters are
       still read while bus control is disabled.

       Exiting the vfs11_vfd driver in a controlled will release the VFD from the bus and restore panel control.

       See the LinuxCNC Integrators Manual for more information. For a  detailed  register  description  of  the
       Toshiba  VFD's,  see  the  "TOSVERT  VF-S11 Communications Function Instruction Manual" (Toshiba document
       number E6581222) and the "TOSVERT VF-S11 Instruction manual" (Toshiba document number E6581158).

AUTHOR

       Michael Haberler; based on gs2_vfd by Steve Padnos and John Thornton.

LICENSE

       GPL