Provided by: dcmtk_3.6.9-5build1_amd64 bug

NAME

       dcm2cda - Extract CDA file from DICOM encapsulated CDA

SYNOPSIS

       dcm2cda [options] dcmfile-in cdafile-out

DESCRIPTION

       The  dcm2cda  utility reads a DICOM file of the Encapsulated CDA Storage SOP Class (dcmfile-in), extracts
       the embedded CDA document and writes it to an output file (cdafile-out).  Optionally  a  command  can  be
       executed after the creation of the CDA file.

PARAMETERS

       dcmfile-in   DICOM input filename ('-' for stdin)

       cdafile-out  CDA output filename

OPTIONS

   general options
         -h   --help
                print this help text and exit

              --version
                print version information and exit

              --arguments
                print expanded command line arguments

         -q   --quiet
                quiet mode, print no warnings and errors

         -v   --verbose
                verbose mode, print processing details

         -d   --debug
                debug mode, print debug information

         -ll  --log-level  [l]evel: string constant
                (fatal, error, warn, info, debug, trace)
                use level l for the logger

         -lc  --log-config  [f]ilename: string
                use config file f for the logger

   input options
       input file format:

         +f   --read-file
                read file format or data set (default)

         +fo  --read-file-only
                read file format only

         -f   --read-dataset
                read data set without file meta information

       input transfer syntax:

         -t=  --read-xfer-auto
                use TS recognition (default)

         -td  --read-xfer-detect
                ignore TS specified in the file meta header

         -te  --read-xfer-little
                read with explicit VR little endian TS

         -tb  --read-xfer-big
                read with explicit VR big endian TS

         -ti  --read-xfer-implicit
                read with implicit VR little endian TS

       parsing of odd-length attributes:

         +ao  --accept-odd-length
                accept odd length attributes (default)

         +ae  --assume-even-length
                assume real length is one byte larger

       handling of undefined length UN elements:

         +ui  --enable-cp246
                read undefined len UN as implicit VR (default)

         -ui  --disable-cp246
                read undefined len UN as explicit VR

       handling of defined length UN elements:

         -uc  --retain-un
                retain elements as UN (default)

         +uc  --convert-un
                convert to real VR if known

       automatic data correction:

         +dc  --enable-correction
                enable automatic data correction (default)

         -dc  --disable-correction
                disable automatic data correction

       bitstream format of deflated input:

         +bd  --bitstream-deflated
                expect deflated bitstream (default)

         +bz  --bitstream-zlib
                expect deflated zlib bitstream

LOGGING

       The  level  of logging output of the various command line tools and underlying libraries can be specified
       by the user. By default, only errors and warnings are written to the standard error stream. Using  option
       --verbose also informational messages like processing details are reported. Option --debug can be used to
       get  more  details  on  the  internal  activity, e.g. for debugging purposes. Other logging levels can be
       selected using option --log-level. In --quiet mode only fatal errors are reported. In  such  very  severe
       error  events,  the application will usually terminate. For more details on the different logging levels,
       see documentation of module 'oflog'.

       In case the logging output should be written to file (optionally with logfile rotation), to syslog (Unix)
       or the event log (Windows) option --log-config can be used.  This  configuration  file  also  allows  for
       directing only certain messages to a particular output stream and for filtering certain messages based on
       the  module  or  application  where  they  are  generated.  An  example configuration file is provided in
       <etcdir>/logger.cfg.

EXIT CODES

       The dcm2cda utility uses the following exit codes when terminating. This enables the user  to  check  for
       the reason why the application terminated.

   general
       EXITCODE_NO_ERROR                         0
       EXITCODE_COMMANDLINE_SYNTAX_ERROR         1

   input file errors
       EXITCODE_CANNOT_READ_INPUT_FILE          20
       EXITCODE_NO_INPUT_FILES                  21
       EXITCODE_INVALID_INPUT_FILE              22

   output file errors
       EXITCODE_CANNOT_WRITE_OUTPUT_FILE        40

COMMAND LINE

       All command line tools use the following notation for parameters: square brackets enclose optional values
       (0-1), three trailing dots indicate that multiple values are allowed (1-n), a combination of both means 0
       to n values.

       Command  line  options  are  distinguished  from  parameters  by a leading '+' or '-' sign, respectively.
       Usually, order and position of command line options  are  arbitrary  (i.e.  they  can  appear  anywhere).
       However,  if  options  are mutually exclusive the rightmost appearance is used. This behavior conforms to
       the standard evaluation rules of common Unix shells.

       In addition, one or more command files can be specified using an '@' sign as a  prefix  to  the  filename
       (e.g.  @command.txt).  Such  a command argument is replaced by the content of the corresponding text file
       (multiple whitespaces are treated as a single separator unless they appear between two  quotation  marks)
       prior  to  any  further  evaluation. Please note that a command file cannot contain another command file.
       This simple but effective approach allows one to summarize common combinations of options/parameters  and
       avoids longish and confusing command lines (an example is provided in file <datadir>/dumppat.txt).

ENVIRONMENT

       The dcm2cda utility will attempt to load DICOM data dictionaries specified in the DCMDICTPATH environment
       variable.   By   default,   i.e.   if   the  DCMDICTPATH  environment  variable  is  not  set,  the  file
       <datadir>/dicom.dic will be loaded unless the dictionary is  built  into  the  application  (default  for
       Windows).

       The  default  behavior  should  be  preferred  and  the  DCMDICTPATH  environment variable only used when
       alternative data dictionaries are required. The DCMDICTPATH environment variable has the same  format  as
       the  Unix  shell  PATH  variable in that a colon (':') separates entries. On Windows systems, a semicolon
       (';') is used as a separator. The data dictionary code will attempt to load each file  specified  in  the
       DCMDICTPATH environment variable. It is an error if no data dictionary can be loaded.