Provided by: procmeter3_3.6-3.1build2_amd64 bug

NAME

       procmetetrc   -   The   procmeterrc  configuration  file  for  procmeter3,  procmeter3-xaw,  gprocmeter3,
       procmeter3-gtk1, procmeter3-gtk2, procmeter3-gtk3, procmeter3-log and procmeter3-lcd programs.

SYNOPSIS

       This file contains the run-time options for the procmeter3, procmeter3-xaw, gprocmeter3, procmeter3-gtk1,
       procmeter3-gtk2, procmeter3-gtk3, procmeter3-log and procmeter3-lcd programs.  These include the  outputs
       that  are  displayed, the colours and fonts that are used (for X window outputs), the LCDproc server (for
       the procmeter-lcd version) and other program options.

DESCRIPTION

       The resources for ProcMeter version 3.x are stored in the .procmeterrc file instead of using X resources.
       This gives more flexibility and allows for much simpler customisation.

       When the procmeter3,  procmeter3-xaw,  gprocmeter3,  procmeter3-gtk1,  procmeter3-gtk2,  procmeter3-gtk3,
       procmeter3-log  or  procmeter3-lcd  programs  start  the .procmeterrc file is searched for in the current
       directory, the current  users  home  directory  or  the  system  default  installation  directory  (named
       procmeterrc).  The file is used from the first one of these locations that matches.

       The  format  of  the .procmeterrc file is a number of sections with the section names marked in '[]'.  As
       well as the fixed sections (described below) there is a section for each module that is named  using  the
       name  that  the  module  reports  itself to be.  There are then further sections for each of the possible
       outputs of each module.  The names of the sections and parameters are not  case  sensitive  although  the
       values  that  they  are  given  may  be.  Lines beginning with the characters ';' or '#' are comments and
       continuation using the '\' character at the end of a line is allowed.

       Below is listed the resource values and the sections of the .procmeterrc file that they can exist in.

library SECTION

       This section contains the information about the ProcMeter modules that are available.   This  applies  to
       all versions of the program.

       path=...
              The  pathname  of  the  library  that  contains  the compiled ProcMeter modules.  (defaults to the
              program's compiled-in installation location).

       others=...
              A list of other modules to be loaded (full pathnames separated by spaces).

startup SECTION

       This section controls how the ProcMeter window should look when the program is started.

       order=...
              A list of the outputs that are to be started up in  the  order  that  they  are  to  be  displayed
              (separated  by  spaces).   If command line options are also specified then they appear after those
              specified here.

resources SECTION

       This section contains the general program display resources.  Not all of the options apply to all of  the
       versions of the program.  Specific versions that the options apply to are specified below.

       horizontal=...
              A  Boolean  to  indicate that the outputs are stacked horizontally instead of the default which is
              vertically. (For X versions of ProcMeter only.)

       background=...
              The colour to use as the default background for all outputs. (An X11 colour name or an  RGB  value
              in hex as #RRGGBB; for X versions of ProcMeter only.)

       foreground=...
              The  colour  to use as the default foreground for all outputs. (An X11 colour name or an RGB value
              in hex as #RRGGBB; for X versions of ProcMeter only.)

       label-font=...
              The font to use for the label that describes the output. (An X11 font name, also  known  as  an  X
              Logical Font Description; for Xaw and GTK1/2 versions of ProcMeter only.)

       label-font-pango=...
              The  font  to use for the label that describes the output. (A Pango font name; for GTK3 version of
              ProcMeter only.)

       label-foreground=...
              The colour to use as the foreground for the label. (An X11 colour name or an RGB value in  hex  as
              #RRGGBB; for X versions of ProcMeter only.)

       label-position=...
              The  position of the label relative to the body of the output.  (Either top, bottom or none; for X
              versions of ProcMeter only.)

       grid-foreground=...
              The colour to use for the grid lines. (An X11 colour name or an RGB value in hex as #RRGGBB; for X
              versions of ProcMeter only.)

       graph-solid=...
              A boolean to indicate if the graph should be solid (the default) or a single line.   (yes  or  no,
              true or false, 0 or 1; for X versions of ProcMeter only.)

       grid-min=...
              The  minimum  number of grid lines to display on a graph or bar chart.  (An integer; for X and LCD
              versions of ProcMeter only.)  This is particularly important with the bar chart because with  this
              set  too  low  the  bar will always be the same length on screen and the number of grid lines will
              change with the data.

       grid-max=...
              The maximum number of grid lines to display on a graph or bar chart.  (An integer; for X  and  LCD
              versions of ProcMeter only.)

       text-font=...
              The  font  to  use  for  the  textual outputs.  (An X11 font name, also known as an X Logical Font
              Description; for Xaw and GTK1/2 versions of ProcMeter only.)

       text-font-pango=...
              The font to use for the textual outputs.  (A Pango font name; for GTK3 version of ProcMeter only.)

       menu-foreground=...
              The colour to use as the foreground for the menus.  (An X11 colour name or an RGB value in hex  as
              #RRGGBB; for Xaw version of ProcMeter only.)

       menu-background=...
              The  colour to use as the background for the menus.  (An X11 colour name or an RGB value in hex as
              #RRGGBB; for Xaw and GTK3 versions of ProcMeter only; the background of all items on the same menu
              must be the same.)

       menu-font=...
              The font to use for the menus.  (An X11 font name, also known as an X  Logical  Font  Description;
              for Xaw version of ProcMeter only.)

       update=...
              The update interval for the output in seconds (an integer).

LCD SECTION

       This section contains parameters that are only used by the procmeter3-lcd version of the program.

       host=...
              The name of the host that the LCDd daemon is running on.

       port=...
              The port number that the LCDd daemon is running on.

       duration=...
              The  length  of time that all of the ProcMeter outputs are displayed on the LCD display for before
              cycling to the next.

       priority=...
              The priority of all of the ProcMeter outputs when they are displayed on  the  LCD  display.   This
              values should be a numeric value for LCDd verions before 0.5 or priority names for later versions.
              Using  numeric  values  will  likely  fail  for LCDd versions after 0.5 due to a bug in LCDd.  The
              safest solution is not to use this option unless you are sure what value to use.

MODULE SECTION

       The name of the section is the name of the ProcMeter module (see the help, procmeter3 -h),  for  example:
       ProcMeter

       These  can contain any of the resource values which will then apply to all outputs of this module.  There
       are also extra options that can be applied to the module and as defaults for the all of  the  outputs  of
       that module.

       options=...
              A  string  containing  options  that  are  passed to the module at startup, different modules have
              different options, see the procmeter3_modules(1) manual page.

       graph-scale=...
              The scaling of the graph or bar chart, the number of units between each of the  grid  lines.   (An
              integer; for X versions of ProcMeter only.)

       run=...
              A string that specifies a program that can be run by selecting it from the menu for the left mouse
              button.   (For  X  versions  of ProcMeter only.)  The way that the command is run can be specified
              using one of the following abbreviations; XTerm( command ) to run command in an xterm  then  exit.
              XTermWait(  command  )  to run command in an xterm and wait for user input before exiting.  Shell(
              command ) to run command in an shell and exit.  This last one is equivalent to using none of these
              abbreviations.

OUTPUT SECTION

       The name of the section is the name of the ProcMeter output (see the help, procmeter3 -h),  for  example:
       ProcMeter.Version

       The  output sections can contain any of the resource or module options (except ´options') which will then
       apply only to the specified output.  There are also options  that  can  only  be  applied  to  individual
       outputs.

       label=...
              Changes the default label for the output to the specified string.

EXAMPLE

       Below  is  an  example  .procmeterrc file, it is a much reduced version of the system default procmeterrc
       file.

        [startup]

        # ProcMeter version, clock, CPU graph, load text
        order=ProcMeter.Version Date_Time.Time_HM \
              Statistics.CPU-g Processes.Load-t

        [resources]

        # The outputs, black on white
        foreground = black
        background = white

        # A large-medium size text font.
        text-font = 8x13
        text-font-pango = Sans 8

        # Solid graphs with at least 5 grid lines in grey.
        graph-solid = yes
        grid-min = 5
        grid-foreground = grey50

        # Black on white output labels, small font, below the data.
        label-font = 5x7
        label-font-pango = Sans 5
        label-foreground = black
        label-position = bottom

        # Black on white menu items in a small-medium size font.
        menu-foreground = black
        menu-background = white
        menu-font = 7x13

        [ProcMeter.Version]

        # A smaller font than normal with no label.
        text-font = 6x10
        text-font-gtk3 = Sans 6
        label-position = none

        [Statistics]

        [Statistics.CPU]

        # The minimum number of grid lines, they are 20% each.
        grid-min = 5

        [Processes]

        run = XTerm(top)

        [Network]

        # To pick up extra devices not automatically recognised.
        #options=ppp0 slip0

FILES

       ./.procmeterrc

       ~/.procmeterrc

       /usr/local/lib/X11/ProcMeter3/procmeterrc or /usr/lib/X11/ProcMeter3/procmeterrc

SEE ALSO

       procmeter3(1),     procmeter3-xaw(1),     gprocmeter3(1),     procmeter3-gtk1(1),     procmeter3-gtk2(1),
       procmeter3-gtk3(1), procmeter3-log(1), procmeter3-lcd(1), procmeter3_modules(1).

AUTHOR

       Andrew M. Bishop (c) 1998-2011

                                                December 30, 2011                                 PROCMETERRC(5)