Provided by: freebsd-manpages_12.2-2_all bug

NAME

       mly — Mylex AcceleRAID/eXtremeRAID family driver

SYNOPSIS

       To compile this driver into the kernel, place the following lines in your kernel configuration file:

             device pci
             device scbus
             device da
             device mly

       Alternatively, to load the driver as a module at boot time, place the following line in loader.conf(5):

             mly_load="YES"

DESCRIPTION

       The  mly driver provides support for Mylex AcceleRAID and eXtremeRAID-family PCI to SCSI RAID controllers
       with version 6.00 and later firmware.

       Logical devices (array drives) attached to the controller are presented to the SCSI subsystem  as  though
       they  were  direct-access  devices  on  a  virtual SCSI bus.  Physical devices which are not claimed by a
       logical device are presented on SCSI channels which match the physical channels on the controller.

HARDWARE

       Controllers supported by the mly driver include:

          Mylex AcceleRAID 160
          Mylex AcceleRAID 170
          Mylex AcceleRAID 352
          Mylex eXtremeRAID 2000
          Mylex eXtremeRAID 3000

       Compatible Mylex controllers not listed should work, but have not been verified.

DIAGNOSTICS

   Controller initialisation phase
       mly%d: controller initialisation started
       mly%d: initialisation complete

       The controller firmware has started initialisation.  Normally this process is performed by the controller
       BIOS, but the driver may need to do this in cases where the BIOS has failed, or is not  compatible  (e.g.
       on non-x86 systems).

       mly%d: drive spinup in progress

       Drive startup is in progress; this may take several minutes.

       mly%d: mirror race recovery failed, one or more drives offline
       mly%d: mirror race recovery in progress
       mly%d: mirror race recovery on a critical drive

       These error codes are undocumented.

       mly%d: FATAL MEMORY PARITY ERROR

       Firmware detected a fatal memory error; the driver will not attempt to attach to this controller.

       mly%d: unknown initialisation code %x

       An unknown error occurred during initialisation; it will be ignored.

   Driver initialisation/shutdown phase
       mly%d: can't enable busmaster feature
       mly%d: memory window not available
       mly%d: can't allocate register window
       mly%d: can't allocate interrupt
       mly%d: can't set up interrupt

       The  system's  PCI  BIOS  has not correctly configured the controller's PCI interface; initialisation has
       failed and the driver will not attach to this controller.

       mly%d: can't allocate parent DMA tag
       mly%d: can't allocate buffer DMA tag
       mly%d: can't allocate command packet DMA tag
       mly%d: can't allocate scatter/gather DMA tag
       mly%d: can't allocate s/g table
       mly%d: can't allocate memory mailbox DMA tag
       mly%d: can't allocate memory mailbox

       A resource allocation error occurred while initialising the driver; initialisation  has  failed  and  the
       driver will not attach to this controller.

       mly%d: BTL rescan result corrupted

       The  results  of  a scan for an attached device were corrupted.  One or more devices may not be correctly
       reported.

       mly%d: flushing cache...

       The controller cache is being flushed prior to detach or shutdown.

   Operational diagnostics
       mly%d: physical device %d:%d online
       mly%d: physical device %d:%d standby
       mly%d: physical device %d:%d automatic rebuild started
       mly%d: physical device %d:%d manual rebuild started
       mly%d: physical device %d:%d rebuild completed
       mly%d: physical device %d:%d rebuild cancelled
       mly%d: physical device %d:%d rebuild failed for unknown reasons
       mly%d: physical device %d:%d rebuild failed due to new physical device
       mly%d: physical device %d:%d rebuild failed due to logical drive failure
       mly%d: physical device %d:%d found
       mly%d: physical device %d:%d gone
       mly%d: physical device %d:%d unconfigured
       mly%d: physical device %d:%d expand capacity started
       mly%d: physical device %d:%d expand capacity completed
       mly%d: physical device %d:%d expand capacity failed
       mly%d: physical device %d:%d parity error
       mly%d: physical device %d:%d soft error
       mly%d: physical device %d:%d miscellaneous error
       mly%d: physical device %d:%d reset
       mly%d: physical device %d:%d active spare found
       mly%d: physical device %d:%d warm spare found
       mly%d: physical device %d:%d initialization started
       mly%d: physical device %d:%d initialization completed
       mly%d: physical device %d:%d initialization failed
       mly%d: physical device %d:%d initialization cancelled
       mly%d: physical device %d:%d write recovery failed
       mly%d: physical device %d:%d scsi bus reset failed
       mly%d: physical device %d:%d double check condition
       mly%d: physical device %d:%d device cannot be accessed
       mly%d: physical device %d:%d gross error on scsi processor
       mly%d: physical device %d:%d bad tag from device
       mly%d: physical device %d:%d command timeout
       mly%d: physical device %d:%d system reset
       mly%d: physical device %d:%d busy status or parity error
       mly%d: physical device %d:%d host set device to failed state
       mly%d: physical device %d:%d selection timeout
       mly%d: physical device %d:%d scsi bus phase error
       mly%d: physical device %d:%d device returned unknown status
       mly%d: physical device %d:%d device not ready
       mly%d: physical device %d:%d device not found at startup
       mly%d: physical device %d:%d COD write operation failed
       mly%d: physical device %d:%d BDT write operation failed
       mly%d: physical device %d:%d missing at startup
       mly%d: physical device %d:%d start rebuild failed due to physical drive too small
       mly%d: physical device %d:%d sense data received
       mly%d:   sense key %d  asc %02x  ascq %02x
       mly%d:   info %4D  csi %4D
       mly%d: physical device %d:%d offline
       mly%d:   sense key %d  asc %02x  ascq %02x
       mly%d:   info %4D  csi %4D

       The reported event refers to the physical device at the given channel:target address.

       mly%d: logical device %d (%s) consistency check started
       mly%d: logical device %d (%s) consistency check completed
       mly%d: logical device %d (%s) consistency check cancelled
       mly%d: logical device %d (%s) consistency check completed with errors
       mly%d: logical device %d (%s) consistency check failed due to logical drive failure
       mly%d: logical device %d (%s) consistency check failed due to physical device failure
       mly%d: logical device %d (%s) automatic rebuild started
       mly%d: logical device %d (%s) manual rebuild started
       mly%d: logical device %d (%s) rebuild completed
       mly%d: logical device %d (%s) rebuild cancelled
       mly%d: logical device %d (%s) rebuild failed for unknown reasons
       mly%d: logical device %d (%s) rebuild failed due to new physical device
       mly%d: logical device %d (%s) rebuild failed due to logical drive failure
       mly%d: logical device %d (%s) offline
       mly%d: logical device %d (%s) critical
       mly%d: logical device %d (%s) online
       mly%d: logical device %d (%s) initialization started
       mly%d: logical device %d (%s) initialization completed
       mly%d: logical device %d (%s) initialization cancelled
       mly%d: logical device %d (%s) initialization failed
       mly%d: logical device %d (%s) found
       mly%d: logical device %d (%s) gone
       mly%d: logical device %d (%s) expand capacity started
       mly%d: logical device %d (%s) expand capacity completed
       mly%d: logical device %d (%s) expand capacity failed
       mly%d: logical device %d (%s) bad block found
       mly%d: logical device %d (%s) size changed
       mly%d: logical device %d (%s) type changed
       mly%d: logical device %d (%s) bad data block found
       mly%d: logical device %d (%s) read of data block in bdt
       mly%d: logical device %d (%s) write back data for disk block lost

       The event report will include the name of the SCSI device which has attached to the device if possible.

       mly%d: enclosure %d fan %d failed
       mly%d: enclosure %d fan %d ok
       mly%d: enclosure %d fan %d not present
       mly%d: enclosure %d power supply %d failed
       mly%d: enclosure %d power supply %d ok
       mly%d: enclosure %d power supply %d not present
       mly%d: enclosure %d temperature sensor %d failed
       mly%d: enclosure %d temperature sensor %d critical
       mly%d: enclosure %d temperature sensor %d ok
       mly%d: enclosure %d temperature sensor %d not present
       mly%d: enclosure %d unit %d access critical
       mly%d: enclosure %d unit %d access ok
       mly%d: enclosure %d unit %d access offline

       These events refer to external enclosures by number.  The driver does not attempt to name the enclosures.

       mly%d: controller cache write back error
       mly%d: controller battery backup unit found
       mly%d: controller battery backup unit charge level low
       mly%d: controller battery backup unit charge level ok
       mly%d: controller installation aborted
       mly%d: controller mirror race recovery in progress
       mly%d: controller mirror race on critical drive
       mly%d: controller memory soft ecc error
       mly%d: controller memory hard ecc error
       mly%d: controller battery backup unit failed

       These events report controller status changes.

AUTHORS

       The mly driver was written by Michael Smith <msmith@FreeBSD.org>.

       This manual page was written by Michael Smith <msmith@FreeBSD.org>.

BUGS

       The driver does not yet provide an external management interface.

       Enclosures are not named or otherwise identified in event messages.

Debian                                           August 10, 2004                                          MLY(4)