Provided by: ipmctl_03.00.00.0485-1build1_amd64 

NAME
ipmctl-start-diagnostic - Starts a diagnostic test
SYNOPSIS
ipmctl start [OPTIONS] -diagnostic [TARGETS]
DESCRIPTION
Starts a diagnostic test.
OPTIONS
-h, -help Displays help for the command. -ddrt Used to specify DDRT as the desired transport protocol for the current invocation of ipmctl. -smbus Used to specify SMBUS as the desired transport protocol for the current invocation of ipmctl. Note The -ddrt and -smbus options are mutually exclusive and may not be used together. -lpmb Used to specify large transport payload size for the current invocation of ipmctl. -spmb Used to specify small transport payload size for the current invocation of ipmctl. Note The -lpmb and -spmb options are mutually exclusive and may not be used together. -o (text|nvmxml), -output (text|nvmxml) Changes the output format. One of: "text" (default) or "nvmxml".
TARGETS
-diagnostic [Quick|Config|Security|FW] Start a specific test by supplying its name. All tests are run by default. One of: • "Quick" - This test verifies that the PMem module host mailbox is accessible and that basic health indicators can be read and are currently reporting acceptable values. • "Config" - This test verifies that the BIOS platform configuration matches the installed hardware and the platform configuration conform to best known practices. • "Security" - This test verifies that all PMem modules have a consistent security state. It is a best practice to enable security on all PMem modules rather than just some. • "FW" - This test verifies that all PMem modules of a given model have consistent FW installed and other FW modifiable attributes are set in accordance with best practices. Note that the test does not have a means of verifying that the installed FW is the optimal version for a given PMem module model just that it has been consistently applied across the system. -dimm [DimmIDS] Starts a diagnostic test on specific PMem modules by optionally supplying one or more comma separated PMem module identifiers. The default is to start the specified tests on all manageable PMem modules. Only valid for the Quick diagnostic test.
EXAMPLES
Starts all diagnostics. ipmctl start -diagnostic Starts the quick check diagnostic on PMem module 0x0001. ipmctl start -diagnostic Quick -dimm 0x0001
LIMITATIONS
If a PMem module is unmanageable, then Quick test will report the reason, while Config, Security and FW tests will skip unmanageable PMem modules.
RETURN DATA
Each diagnostic generates one or more log messages. A successful test generates a single log message per PMem module indicating that no errors were found. A failed test might generate multiple log messages each highlighting a specific error with all the relevant details. Each log contains the following information. Test The test name along with overall execution result. One of: • "Quick" • "Config" • "Security" • "FW" State The collective result state for each test. One of: • "Ok" • "Warning" • "Failed" • "Aborted" Message The message indicates the status of the test. One of: • "Ok" • "Failed" SubTestName The subtest name for given Test. ┌───────────┬──────────────────────────────────┐ │ │ │ │ Test Name │ Valid SubTest Names │ ├───────────┼──────────────────────────────────┤ │ │ │ │ Quick │ │ │ │ • Manageability │ │ │ │ │ │ • Boot status │ │ │ │ │ │ • Health │ ├───────────┼──────────────────────────────────┤ │ │ │ │ Config │ │ │ │ • PMem module specs │ │ │ │ │ │ • Duplicate PMem module │ │ │ │ │ │ • System Capability │ │ │ │ │ │ • Namespace LSA │ │ │ │ │ │ • PCD │ ├───────────┼──────────────────────────────────┤ │ │ │ │ Security │ │ │ │ • Encryption status │ │ │ │ │ │ • Inconsistency │ ├───────────┼──────────────────────────────────┤ │ │ │ │ FW │ │ │ │ • FW Consistency │ │ │ │ │ │ • Viral Policy │ │ │ │ │ │ • Threshold check │ │ │ │ │ │ • System Time │ └───────────┴──────────────────────────────────┘ State The severity of the error for each sub-test displayed with SubTestName. One of: • "Ok" • "Warning" • "Failed" • "Aborted" Events are generated as a result of invoking the Start Diagnostics command in order to analyze the Intel® Optane™ PMem module for potential issues. Diagnostic events may fall into the following categories: • Quick health diagnostic test event • Platform configuration diagnostic test event • Security diagnostic test event • Firmware consistency and settings diagnostic test event Each event includes the following pieces of information: • The severity of the event that occurred. One of: • Informational (Info) • Warning (Warning) • Error (Failed) • Aborted (Aborted) • A unique ID of the item (PMem module UUID, DimmID, NamespaceID, RegionID, etc.) the event refers to. • A detailed description of the event in English. The following sections list each of the possible events grouped by category of the event. Quick Health Check Events The quick health check diagnostic verifies that the Intel® Optane™ PMem module’s host mailboxes are accessible and that basic health indicators can be read and are currently reporting acceptable values. Table 1. Table Quick Health Check Events ┌──────┬──────────┬────────────────────────┬────────────────────────┐ │ │ │ │ │ │ Code │ Severity │ Message │ Arguments │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 500 │ Info │ The quick health check │ │ │ │ │ succeeded. │ │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 501 │ Warning │ The quick health check │ │ │ │ │ detected that PMem │ 1. PMem module │ │ │ │ module [1] is not │ Handle │ │ │ │ manageable because │ │ │ │ │ subsystem vendor ID │ 2. Subsystem │ │ │ │ [2] is not supported. │ Vendor ID │ │ │ │ UID: [3] │ │ │ │ │ │ 3. PMem module │ │ │ │ │ UID │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 502 │ Warning │ The quick health check │ │ │ │ │ detected that PMem │ 1. PMem module │ │ │ │ module [1] is not │ Handle │ │ │ │ manageable because │ │ │ │ │ subsystem device ID │ 2. Subsystem │ │ │ │ [2] is not supported. │ Device ID │ │ │ │ UID: [3] │ │ │ │ │ │ 3. PMem module │ │ │ │ │ UID │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 503 │ Warning │ The quick health check │ │ │ │ │ detected that PMem │ 1. PMem module │ │ │ │ module [1] is not │ Handle │ │ │ │ manageable because │ │ │ │ │ firmware API version │ 2. FW API │ │ │ │ [2] is not supported. │ version │ │ │ │ UID: [3] │ │ │ │ │ │ 3. PMem module │ │ │ │ │ UID │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 504 │ Warning │ The quick health check │ │ │ │ │ detected that PMem │ 1. PMem module │ │ │ │ module [1] is │ Handle │ │ │ │ reporting a bad health │ │ │ │ │ state [2]. UID: [3] │ 2. Actual │ │ │ │ │ Health │ │ │ │ │ State │ │ │ │ │ │ │ │ │ │ 3. PMem module │ │ │ │ │ UID │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 505 │ Warning │ The quick health check │ │ │ │ │ detected that PMem │ 1. PMem module │ │ │ │ module [1] is │ Handle │ │ │ │ reporting a media │ │ │ │ │ temperature of [2] C │ 2. Actual │ │ │ │ which is above the │ Media │ │ │ │ alarm threshold [3] C. │ Temperature │ │ │ │ UID: [4] │ │ │ │ │ │ 3. Media │ │ │ │ │ Temperature │ │ │ │ │ Threshold │ │ │ │ │ │ │ │ │ │ 4. PMem module │ │ │ │ │ UID │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 506 │ Warning │ The quick health check │ │ │ │ │ detected that PMem │ 1. PMem module │ │ │ │ module [1] is │ Handle │ │ │ │ reporting percentage │ │ │ │ │ remaining at [2]% │ 2. Actual │ │ │ │ which is less than the │ Percentage │ │ │ │ alarm threshold [3]%. │ Remaining │ │ │ │ UID: [4] │ │ │ │ │ │ 3. Percentage │ │ │ │ │ Remaining │ │ │ │ │ Threshold │ │ │ │ │ │ │ │ │ │ 4. PMem module │ │ │ │ │ UID │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 507 │ Warning │ The quick health check │ │ │ │ │ detected that PMem │ 1. PMem module │ │ │ │ module [1] is │ Handle │ │ │ │ reporting reboot │ │ │ │ │ required. UID: [2] │ 2. PMem module │ │ │ │ │ UID │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 511 │ Warning │ The quick health check │ │ │ │ │ detected that PMem │ 1. PMem module │ │ │ │ module [1] is │ Handle │ │ │ │ reporting a controller │ │ │ │ │ temperature of [2] C │ 2. Actual │ │ │ │ which is above the │ Controller │ │ │ │ alarm threshold [3] C. │ Temperature │ │ │ │ UID: [4] │ │ │ │ │ │ 3. Controller │ │ │ │ │ Temperature │ │ │ │ │ Threshold │ │ │ │ │ │ │ │ │ │ 4. PMem module │ │ │ │ │ UID │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 513 │ Error │ The quick health check │ │ │ │ │ detected that the boot │ 1. PMem module │ │ │ │ status register of │ Handle │ │ │ │ PMem module [1] is not │ │ │ │ │ readable. UID: [2] │ 2. PMem module │ │ │ │ │ UID │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 514 │ Error │ The quick health check │ │ │ │ │ detected that the │ 1. PMem module │ │ │ │ firmware on PMem │ Handle │ │ │ │ module [1] is │ │ │ │ │ reporting that the │ 2. PMem module │ │ │ │ media is not ready. │ UID │ │ │ │ UID: [2] │ │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 515 │ Error │ The quick health check │ │ │ │ │ detected that the │ 1. PMem module │ │ │ │ firmware on PMem │ Handle │ │ │ │ module [1] is │ │ │ │ │ reporting an error in │ 2. PMem module │ │ │ │ the media. UID: [2] │ UID │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 519 │ Error │ The quick health check │ │ │ │ │ detected that PMem │ 1. PMem module │ │ │ │ module [1] failed to │ Handle │ │ │ │ initialize BIOS POST │ │ │ │ │ testing. UID: [2] │ 2. PMem module │ │ │ │ │ UID │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 520 │ Error │ The quick health check │ │ │ │ │ detected that the │ 1. PMem module │ │ │ │ firmware on PMem │ Handle │ │ │ │ module [1] has not │ │ │ │ │ initialized │ 2. Major │ │ │ │ successfully. The last │ checkpoint │ │ │ │ known Major:Minor │ : Minor │ │ │ │ Checkpoint is [2]. │ checkpoint │ │ │ │ UID: [3] │ in Boot │ │ │ │ │ Status │ │ │ │ │ Register │ │ │ │ │ │ │ │ │ │ 3. PMem module │ │ │ │ │ UID │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 523 │ Error │ The quick health check │ │ │ │ │ detected that PMem │ 1. PMem module │ │ │ │ module [1] is │ Handle │ │ │ │ reporting a viral │ │ │ │ │ state. The PMem module │ 2. PMem module │ │ │ │ is now read-only. UID: │ UID │ │ │ │ [2] │ │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 529 │ Warning │ The quick health check │ │ │ │ │ detected that PMem │ 1. PMem module │ │ │ │ module [1] is │ Handle │ │ │ │ reporting that it has │ │ │ │ │ no package spares │ 2. PMem module │ │ │ │ available. UID: [2] │ UID │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 530 │ Info │ The quick health check │ │ │ │ │ detected that the │ 1. PMem module │ │ │ │ firmware on PMem │ Handle │ │ │ │ module [1] experienced │ │ │ │ │ an unsafe shutdown │ 2. PMem module │ │ │ │ before its latest │ UID │ │ │ │ restart. UID: [2] │ │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 533 │ Error │ The quick health check │ │ │ │ │ detected that the │ 1. PMem module │ │ │ │ firmware on PMem │ Handle │ │ │ │ module [1] is │ │ │ │ │ reporting that the AIT │ 2. PMem module │ │ │ │ DRAM is not ready. │ UID │ │ │ │ UID: [2] │ │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 534 │ Error │ The quick health check │ │ │ │ │ detected that the │ 1. PMem module │ │ │ │ firmware on PMem │ Handle │ │ │ │ module [1] is │ │ │ │ │ reporting that the │ 2. PMem module │ │ │ │ media is disabled. │ UID │ │ │ │ UID: [2] │ │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 535 │ Error │ The quick health check │ │ │ │ │ detected that the │ 1. PMem module │ │ │ │ firmware on PMem │ Handle │ │ │ │ module [1] is │ │ │ │ │ reporting that the AIT │ 2. PMem module │ │ │ │ DRAM is disabled. UID: │ UID │ │ │ │ [2] │ │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 536 │ Error │ The quick health check │ │ │ │ │ detected that the │ 1. PMem module │ │ │ │ firmware on PMem │ Handle │ │ │ │ module [1] failed to │ │ │ │ │ load successfully. │ 2. PMem module │ │ │ │ UID: [2] │ UID │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 538 │ Error │ PMem module [1] is │ │ │ │ │ reporting that the │ 1. PMem module │ │ │ │ DDRT IO Init is not │ Handle │ │ │ │ complete. UID: [2] │ │ │ │ │ │ 2. PMem module │ │ │ │ │ UID │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 539 │ Error │ PMem module [1] is │ │ │ │ │ reporting that the │ 1. PMem module │ │ │ │ mailbox interface is │ Handle │ │ │ │ not ready. UID: [2] │ │ │ │ │ │ 2. PMem module │ │ │ │ │ UID │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 540 │ Error │ An internal error │ │ │ │ │ caused the quick │ 1. PMem module │ │ │ │ health check to abort │ Handle │ │ │ │ on PMem module [1]. │ │ │ │ │ UID: [2] │ 2. PMem module │ │ │ │ │ UID │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 541 │ Error │ The quick health check │ │ │ │ │ detected that PMem │ 1. PMem module │ │ │ │ module [1] is busy. │ Handle │ │ │ │ UID: [2] │ │ │ │ │ │ 2. PMem module │ │ │ │ │ UID │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 542 │ Error │ The quick health check │ │ │ │ │ detected that the │ 1. PMem module │ │ │ │ platform FW did not │ Handle │ │ │ │ map a region to SPA on │ │ │ │ │ PMem module [1]. ACPI │ 2. PMem module │ │ │ │ NFIT NVPMem module │ UID │ │ │ │ State Flags Error Bit │ │ │ │ │ 6 Set. UID: [2] │ │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 543 │ Error │ The quick health check │ │ │ │ │ detected that PMem │ 1. PMem module │ │ │ │ module [1] DDRT │ Handle │ │ │ │ Training is not │ │ │ │ │ complete/failed. UID: │ 2. PMem module │ │ │ │ [2] │ UID │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 544 │ Error │ PMem module [1] is │ │ │ │ │ reporting that the │ 1. PMem module │ │ │ │ DDRT IO Init is not │ Handle │ │ │ │ started. UID: [2] │ │ │ │ │ │ 2. PMem module │ │ │ │ │ UID │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 545 │ Error │ The quick health check │ │ │ │ │ detected that the ROM │ 1. PMem module │ │ │ │ on PMem module [1] has │ Handle │ │ │ │ failed to complete │ │ │ │ │ initialization, last │ 2. Major │ │ │ │ known Major:Minor │ checkpoint │ │ │ │ Checkpoint is [2]. │ : Minor │ │ │ │ │ checkpoint │ │ │ │ │ in Boot │ │ │ │ │ Status │ │ │ │ │ Register │ │ │ │ │ │ │ │ │ │ 3. PMem module │ │ │ │ │ UID │ └──────┴──────────┴────────────────────────┴────────────────────────┘ Platform Configuration Check Events This diagnostic test group verifies that the BIOS platform configuration matches the installed hardware and the platform configuration conforms to best known practices. Table 2. Table Platform Configuration Check Events ┌──────┬──────────┬───────────────────────────────┬──────────────────────────┐ │ │ │ │ │ │ Code │ Severity │ Message │ Arguments │ ├──────┼──────────┼───────────────────────────────┼──────────────────────────┤ │ │ │ │ │ │ 600 │ Info │ The platform │ │ │ │ │ configuration check │ │ │ │ │ succeeded. │ │ ├──────┼──────────┼───────────────────────────────┼──────────────────────────┤ │ │ │ │ │ │ 601 │ Info │ The platform │ │ │ │ │ configuration check │ │ │ │ │ detected that there │ │ │ │ │ are no manageable PMem │ │ │ │ │ modules. │ │ ├──────┼──────────┼───────────────────────────────┼──────────────────────────┤ │ │ │ │ │ │ 606 │ Info │ The platform │ │ │ │ │ configuration check │ 1. PMem module │ │ │ │ detected that PMem │ Handle │ │ │ │ module [1] is not │ │ │ │ │ configured. UID: [2] │ 2. PMem module │ │ │ │ │ UID │ ├──────┼──────────┼───────────────────────────────┼──────────────────────────┤ │ │ │ │ │ │ 608 │ Error │ The platform │ │ │ │ │ configuration check │ 1. Number of │ │ │ │ detected [1] PMem │ PMem │ │ │ │ modules installed on │ modules │ │ │ │ the platform with the │ with │ │ │ │ same serial number │ duplicate │ │ │ │ [2]. │ serial │ │ │ │ │ numbers. │ │ │ │ │ │ │ │ │ │ 2. The │ │ │ │ │ duplicate │ │ │ │ │ serial │ │ │ │ │ number │ ├──────┼──────────┼───────────────────────────────┼──────────────────────────┤ │ │ │ │ │ │ 609 │ Info │ The platform │ │ │ │ │ configuration check │ 1. PMem module │ │ │ │ detected that PMem │ Handle │ │ │ │ module [1] has a goal │ │ │ │ │ configuration that has │ 2. PMem module │ │ │ │ not yet been applied. │ UID │ │ │ │ A system reboot is │ │ │ │ │ required for the new │ │ │ │ │ configuration to take │ │ │ │ │ effect. UID: [2] │ │ ├──────┼──────────┼───────────────────────────────┼──────────────────────────┤ │ │ │ │ │ │ 618 │ Error │ The platform │ │ │ │ │ configuration check │ 1. PMem module │ │ │ │ detected that a PMem │ handle in │ │ │ │ module with physical │ the SMBIOS │ │ │ │ ID [1] is present in │ table │ │ │ │ the system but failed │ │ │ │ │ to initialize. UID: │ 2. PMem module │ │ │ │ [2] │ UID │ ├──────┼──────────┼───────────────────────────────┼──────────────────────────┤ │ │ │ │ │ │ 621 │ Error │ The platform │ │ │ │ │ configuration check │ 1. PMem module │ │ │ │ detected PCD contains │ Handle │ │ │ │ invalid data on PMem │ │ │ │ │ module [1]. UID: [2] │ 2. PMem module │ │ │ │ │ UID │ ├──────┼──────────┼───────────────────────────────┼──────────────────────────┤ │ │ │ │ │ │ 622 │ Error │ The platform │ │ │ │ │ configuration check │ │ │ │ │ was unable to retrieve │ │ │ │ │ the namespace │ │ │ │ │ information. │ │ ├──────┼──────────┼───────────────────────────────┼──────────────────────────┤ │ │ │ │ │ │ 623 │ Warning │ The platform │ │ │ │ │ configuration check │ │ │ │ │ detected that the BIOS │ │ │ │ │ settings do not │ │ │ │ │ currently allow memory │ │ │ │ │ provisioning from this │ │ │ │ │ software. │ │ ├──────┼──────────┼───────────────────────────────┼──────────────────────────┤ │ │ │ │ │ │ 624 │ Error │ The platform │ │ │ │ │ configuration check │ 1. PMem module │ │ │ │ detected that the BIOS │ Handle │ │ │ │ could not apply the │ │ │ │ │ configuration goal on │ 2. Validation │ │ │ │ PMem module [1] │ Status │ │ │ │ because of errors in │ │ │ │ │ the goal data. The │ 3. Text error │ │ │ │ detailed status is │ code │ │ │ │ COUT table status: [2] │ corresponding │ │ │ │ [3], Partition change │ to the │ │ │ │ table status: [4], │ status code │ │ │ │ Interleave change │ │ │ │ │ table 1 status: [5], │ 4. Partition │ │ │ │ Interleave change │ Size Change │ │ │ │ table 2 status: [6]. │ Status │ │ │ │ │ │ │ │ │ │ 5. Interleave │ │ │ │ │ Change │ │ │ │ │ Status │ │ │ │ │ │ │ │ │ │ 6. Interleave │ │ │ │ │ Change │ │ │ │ │ Status │ ├──────┼──────────┼───────────────────────────────┼──────────────────────────┤ │ │ │ │ │ │ 625 │ Error │ The platform │ │ │ │ │ configuration check │ 1. PMem module │ │ │ │ detected that the BIOS │ Handle │ │ │ │ could not apply the │ │ │ │ │ configuration goal on │ 2. Validation │ │ │ │ PMem module [1] │ Status │ │ │ │ because the system has │ │ │ │ │ insufficient │ 3. Text error │ │ │ │ resources. The │ code │ │ │ │ detailed status is │ corresponding │ │ │ │ COUT table status: [2] │ to the status │ │ │ │ [3], Partition change │ code │ │ │ │ table status: [4], │ │ │ │ │ Interleave change │ 4. Partition │ │ │ │ table 1 status: [5], │ Size Change │ │ │ │ Interleave change │ Status │ │ │ │ table 2 status: [6]. │ │ │ │ │ │ 5. Interleave │ │ │ │ │ Change Status │ │ │ │ │ │ │ │ │ │ 6. Interleave │ │ │ │ │ Change Status │ ├──────┼──────────┼───────────────────────────────┼──────────────────────────┤ │ │ │ │ │ │ 626 │ Error │ The platform │ │ │ │ │ configuration check │ 1. PMem module │ │ │ │ detected that the BIOS │ Handle │ │ │ │ could not apply the │ │ │ │ │ configuration goal on │ 2. Validation │ │ │ │ PMem module [1] │ Status │ │ │ │ because of a firmware │ │ │ │ │ error. The detailed │ 3. Text error │ │ │ │ status is COUT table │ code │ │ │ │ status: [2] [3], │ corresponding │ │ │ │ Partition change table │ to the status │ │ │ │ status: [4], │ code │ │ │ │ Interleave change │ │ │ │ │ table 1 status: [5], │ 4. Partition │ │ │ │ Interleave change │ Size Change │ │ │ │ table 2 status: [6]. │ Status │ │ │ │ │ │ │ │ │ │ 5. Interleave │ │ │ │ │ Change Status │ │ │ │ │ │ │ │ │ │ 6. Interleave │ │ │ │ │ Change Status │ ├──────┼──────────┼───────────────────────────────┼──────────────────────────┤ │ │ │ │ │ │ 627 │ Error │ The platform │ │ │ │ │ configuration check │ 1. PMem module │ │ │ │ detected that the BIOS │ Handle │ │ │ │ could not apply the │ │ │ │ │ configuration goal on │ 2. Validation │ │ │ │ PMem module [1] for an │ Status │ │ │ │ unknown reason. The │ │ │ │ │ detailed status is │ 3. Text error │ │ │ │ COUT table status: [2] │ code │ │ │ │ [3], Partition change │ corresponding │ │ │ │ table status: [4], │ to the status │ │ │ │ Interleave change │ code │ │ │ │ table 1 status: [5], │ │ │ │ │ Interleave change │ 4. Partition │ │ │ │ table 2 status: [6]. │ Size Change │ │ │ │ │ Status │ │ │ │ │ │ │ │ │ │ 5. Interleave │ │ │ │ │ Change Status │ │ │ │ │ │ │ │ │ │ 6. Interleave │ │ │ │ │ Change Status │ ├──────┼──────────┼───────────────────────────────┼──────────────────────────┤ │ │ │ │ │ │ 628 │ Error │ The platform │ │ │ │ │ configuration check │ 1. Interleave │ │ │ │ detected that │ set index ID │ │ │ │ interleave set [1] is │ │ │ │ │ broken because the │ 2. List of moved │ │ │ │ PMem modules were │ PMem modules. │ │ │ │ moved [2]. │ │ ├──────┼──────────┼───────────────────────────────┼──────────────────────────┤ │ │ │ │ │ │ 629 │ Error │ The platform │ │ │ │ │ configuration check │ │ │ │ │ detected that the │ │ │ │ │ platform does not │ │ │ │ │ support ADR and │ │ │ │ │ therefore data │ │ │ │ │ integrity is not │ │ │ │ │ guaranteed on the PMem │ │ │ │ │ modules. │ │ ├──────┼──────────┼───────────────────────────────┼──────────────────────────┤ │ │ │ │ │ │ 630 │ Error │ An internal error │ │ │ │ │ caused the platform │ │ │ │ │ configuration check to │ │ │ │ │ abort. │ │ ├──────┼──────────┼───────────────────────────────┼──────────────────────────┤ │ │ │ │ │ │ 631 │ Error │ The platform │ │ │ │ │ configuration check │ 1. Interleave │ │ │ │ detected that │ set index ID │ │ │ │ interleave set [1] is │ │ │ │ │ broken because the │ 2. PMem module │ │ │ │ PMem module with UID: │ UID │ │ │ │ [2] is missing from │ │ │ │ │ location │ 3. Location ID │ │ │ │ (Socket-Die-iMC-Channel-Slot) │ │ │ │ │ [3]. │ │ ├──────┼──────────┼───────────────────────────────┼──────────────────────────┤ │ │ │ │ │ │ 632 │ Error │ The platform configuration │ │ │ │ │ check detected that │ 1. Interleave │ │ │ │ interleave set [1] is broken │ set index ID │ │ │ │ because the PMem module with │ │ │ │ │ UID: [2] is misplaced. It is │ 2. PMem module │ │ │ │ currently in location │ UID │ │ │ │ (Socket-Die-iMC-Channel-Slot) │ │ │ │ │ [3] and should be moved to │ 3. Location ID │ │ │ │ (Socket-Die-iMC-Channel-Slot) │ │ │ │ │ [4]. │ 4. Location ID │ ├──────┼──────────┼───────────────────────────────┼──────────────────────────┤ │ │ │ │ │ │ 633 │ Error │ The platform configuration │ │ │ │ │ check detected that the BIOS │ 1. PMem module │ │ │ │ could not fully map memory on │ Handle │ │ │ │ PMem module [1] because of an │ │ │ │ │ error in current │ 2. Current │ │ │ │ configuration. The detailed │ Configuration │ │ │ │ status is CCUR table status: │ Status │ │ │ │ [2] [3]. │ │ │ │ │ │ 3. Text error │ │ │ │ │ code │ │ │ │ │ corresponding │ │ │ │ │ to the status │ │ │ │ │ code │ └──────┴──────────┴───────────────────────────────┴──────────────────────────┘ Security Check Events The security check diagnostic test group verifies that all Intel® Optane™ PMem modules have a consistent security state. Table 3. Table Security Check Events ┌──────┬──────────┬────────────────────────┬────────────────────────┐ │ │ │ │ │ │ Code │ Severity │ Message │ Arguments │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 800 │ Info │ The security check │ │ │ │ │ succeeded. │ │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 801 │ Info │ The security check │ │ │ │ │ detected that there │ │ │ │ │ are no manageable PMem │ │ │ │ │ modules. │ │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 802 │ Warning │ The security check │ │ │ │ │ detected that security │ 1. A comma │ │ │ │ settings are │ separated │ │ │ │ inconsistent [1]. │ list of the │ │ │ │ │ number of │ │ │ │ │ PMem │ │ │ │ │ modules in │ │ │ │ │ each │ │ │ │ │ security │ │ │ │ │ state │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 804 │ Info │ The security check │ │ │ │ │ detected that security │ │ │ │ │ is not supported on │ │ │ │ │ all PMem modules. │ │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 805 │ Error │ An internal error │ │ │ │ │ caused the security │ │ │ │ │ check to abort. │ │ └──────┴──────────┴────────────────────────┴────────────────────────┘ Firmware Consistency and Settings Check Events This test group verifies that all PMem modules of a given subsystem device ID have consistent FW installed and other FW modifiable attributes are set in accordance with best practices. Table 4. Table Firmware Consistency and Settings Check Events ┌──────┬──────────┬────────────────────────┬────────────────────────┐ │ │ │ │ │ │ Code │ Severity │ Message │ Arguments │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 900 │ Info │ The firmware │ │ │ │ │ consistency and │ │ │ │ │ settings check │ │ │ │ │ succeeded. │ │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 901 │ Info │ The firmware │ │ │ │ │ consistency and │ │ │ │ │ settings check │ │ │ │ │ detected that there │ │ │ │ │ are no manageable PMem │ │ │ │ │ modules. │ │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 902 │ Warning │ The firmware │ │ │ │ │ consistency and │ 1. Comma │ │ │ │ settings check │ separated │ │ │ │ detected that firmware │ list of │ │ │ │ version on PMem │ PMem module │ │ │ │ modules [1] with │ UIDs │ │ │ │ subsystem device ID │ │ │ │ │ [2] is non-optimal, │ 2. Subsystem │ │ │ │ preferred version is │ device ID │ │ │ │ [3]. │ │ │ │ │ │ 3. Preferred │ │ │ │ │ firmware │ │ │ │ │ version │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 903 │ Warning │ The firmware │ │ │ │ │ consistency and │ 1. PMem module │ │ │ │ settings check │ Handle │ │ │ │ detected that PMem │ │ │ │ │ module [1] is │ 2. Current │ │ │ │ reporting a │ media │ │ │ │ non-critical media │ temperature │ │ │ │ temperature threshold │ threshold │ │ │ │ of [2] C which is │ │ │ │ │ above the fatal │ 3. Fatal media │ │ │ │ threshold [3] C. UID: │ temperature │ │ │ │ [4] │ threshold │ │ │ │ │ │ │ │ │ │ 4. PMem module │ │ │ │ │ UID │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 904 │ Warning │ The firmware │ │ │ │ │ consistency and │ 1. PMem module │ │ │ │ settings check │ Handle │ │ │ │ detected that PMem │ │ │ │ │ module [1] is │ 2. Current │ │ │ │ reporting a │ controller │ │ │ │ non-critical │ temperature │ │ │ │ controller temperature │ threshold │ │ │ │ threshold of [2] C │ │ │ │ │ which is above the │ 3. Fatal │ │ │ │ fatal threshold [3] C. │ controller │ │ │ │ UID: [4] │ temperature │ │ │ │ │ threshold │ │ │ │ │ │ │ │ │ │ 4. PMem module │ │ │ │ │ UID │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 905 │ Warning │ The firmware │ │ │ │ │ consistency and │ 1. PMem module │ │ │ │ settings check │ Handle │ │ │ │ detected that PMem │ │ │ │ │ module [1] is │ 2. Current │ │ │ │ reporting a percentage │ percentage │ │ │ │ remaining of [2]% │ remaining │ │ │ │ which is below the │ threshold │ │ │ │ recommended threshold │ │ │ │ │ [3]%. UID: [4] │ 3. Recommended │ │ │ │ │ percentage │ │ │ │ │ remaining │ │ │ │ │ threshold │ │ │ │ │ │ │ │ │ │ 4. PMem module │ │ │ │ │ UID │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 906 │ Warning │ The firmware │ │ │ │ │ consistency and │ │ │ │ │ settings check │ │ │ │ │ detected that PMem │ │ │ │ │ modules have │ │ │ │ │ inconsistent viral │ │ │ │ │ policy settings. │ │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 910 │ Error │ An internal error │ │ │ │ │ caused the firmware │ │ │ │ │ consistency and │ │ │ │ │ settings check to │ │ │ │ │ abort. │ │ ├──────┼──────────┼────────────────────────┼────────────────────────┤ │ │ │ │ │ │ 911 │ Warning │ The firmware │ │ │ │ │ consistency and │ │ │ │ │ settings check │ │ │ │ │ detected that PMem │ │ │ │ │ modules have │ │ │ │ │ inconsistent first │ │ │ │ │ fast refresh settings. │ │ └──────┴──────────┴────────────────────────┴────────────────────────┘ ipmctl 2024-04-22 IPMCTL-START-DIAGNOSTIC(1)