Provided by: libncarg-dev_6.6.2.dfsg.1-10build2_amd64 bug

NAME

       Conran_family_params - Includes a brief description of all Conran_family internal parameters.

DESCRIPTION

       There are three Conran entries, CONRAN, CONRAQ, and CONRAS.  CONRAN can be invoked in two ways.  One
       generates smoothed contours, the other does not.  CONRAQ is a quick version of the package which has a
       more limited set of options than the other entries.  CONRAS is the super version of the package.

       Parameters are set using the CONOP1, CONOP2, CONOP3, and CONOP4 entries.  CONOP1 sets option switches,
       CONOP2 sets option switches and option related integer arguments, CONOP3 sets option switches and option
       related real arguments, and CONOP4 sets option switches and option related character arguments.  This man
       page provides a functional overview of the parameters.  See the man pages for the CONOPx entries for
       precise information on how to make the option setting calls.

       All of the following parameters apply to normal, smooth, or super versions of the package.  The inclusive
       set of Conran parameters and their switch defaults:

       CONOP1 parameters  (Switches)   [16]

          DEF (all options begin with defaults)
          EXT=OFF   MES=ON    REP=OFF
          GRI=OFF   PDV=OFF   SCA=ON
          ITP=C1    PER=ON    TFR=ON
          LAB=ON    PMM=OFF   TOP=OFF
          LOT=OFF   PSL=OFF   TRI=OFF

       CONOP2 parameters  (Switches & Integer args)   [7]

          INT=OFF LSZ=OFF NCP=OFF SML=OFF
          SPD=OFF SSZ=OFF STL=OFF

       CONOP3 parameters  (Switches & Real args)      [7]

          CHL=OFF CIL=OFF CON=OFF DBP=OFF
          SDC=OFF SLD=OFF TEN=OFF

       CONOP4 parameters  (Switches & Character args)  [3]

          DAS=OFF FMT=OFF TLE=OFF

       Parameters which are not available in CONRAQ, the quick version of the Conran_family:

       DAS, DBP, LAB, LSZ, PMM, PSL, SDC, SLD, SML, TEN

Parameters which set option switches in calls to entry CONOP1:

       DEF         This parameter provides a quick way to reset all parameters to their default values.

       EXT         A parameter to set contour extrapolations.  The default is to only plot within the boundaries
                   of  the  convex  hull  defined by the user's data.  To have the contours fill the rectangular
                   area of the frame, set the EXT switch ON.

       GRI         The parameter to display the grid.  GRI is OFF by default.  Note: If GRI=ON, the virtual grid
                   will be superimposed over the contour plot.  The X and Y tick  intervals  will  be  displayed
                   under the map only if PER=ON.  (See parameter PER)

       ITP         Set  the  interpolation  scheme.   There are two schemes  --  C1 surfaces and linear.  The C1
                   method (ITP=C1) takes longer but will give the best results when the  data  is  sparse  (less
                   than  100  points).   The  linear method (ITP=LIN) will produce a better plot when there is a
                   dense data set.  The default is a C1 surface.

       LAB         This parameter determines whether to label the  contours  (LAB=ON)  or  not  (LAB=OFF).   The
                   default value is to label the contours.  (Does not apply to entry CONRAQ.)

       LOT         The  parameter  to  list  options  on  the  printer.  The default value is to not display the
                   options.

       MES         The parameter to plot a message.  The default is that a message is  printed  below  the  plot
                   giving  contour  intervals  and  execution time in seconds.  If PER or GRI is ON, the message
                   also contains the X and Y tick intervals.

       PDV         The parameter to plot the input data values.  The default value is  to  not  plot  the  input
                   data.

       PER         The  parameter  to  draw  a perimeter.  The default is to draw a perimeter around the contour
                   plot.

       PMM         The parameter to plot relative minima and maxima.  The default is to not  plot  them.   (Does
                   not apply to entry CONRAQ.)

       PSL         The  parameter  which  determines whether the outline of the data shield will be drawn on the
                   same frame as the contour plot.  The default is to not draw the shield.  (Does not  apply  to
                   entry CONRAQ.)

       REP         The  parameter  indicating the use of the same data in a new execution.  The default value is
                   to assume a new input dataset.

       SCA         The parameter for scaling of the plot on a frame.  This parameter is ON by default.

       TFR         The parameter to advance the frame before triangulation.  The default value is TFR=ON,  which
                   means that the contours and the triangles will be plotted on separate frames.

       TOP         The parameter to plot only the triangles.  The default is to plot contours, then triangles.

       TRI         The  parameter to plot the triangulation.  The default is OFF and therefore the triangles are
                   not drawn.

Parameters of type INTEGER set in calls to entry CONOP2:

       INT         The parameter to determine line intensities for various parts of the plot.  Intensities  vary
                   from a high of 255 to a low of 0.  The default is high for all parts of the plot except minor
                   contour lines which are set to low.

       LSZ         This  parameter  determines  the  character  size of contour labels.  The default value is 9,
                   which results in label characters of a size of 9./1023. NDC units.  (Does not apply to  entry
                   CONRAQ.)

       NCP         The  parameter  NCP  controls  the  number  of  data  points to be used in the interpolation.
                   Increasing NCP causes more of the  surrounding data to influence the point of  interpolation.
                   In  the  case  of linear interpolation NCP is always 4.  In the case of C1 interpolation, NCP
                   can vary from 2 to 25 with 4 as the default.

                   The interpolation option is selected using internal parameter ITP.

       SML         This parameter specifies the character size of  minimum  and  maximum  contour  labels.   The
                   default  value  is  15, which results in label character sizes of 15./1023. NDC units.  (Does
                   not apply to entry CONRAQ.)

       SPD         The parameter for the size of the plotted input data values.  The default value is  8,  which
                   results in a data value character size of 8./1023. NDC units.

       SSZ         The  parameter  to determine the resolution (number of steps in each direction).  The default
                   is 40.

       STL         The parameter to determine the size of the main title characters.  The default value  is  16,
                   which results in title character sizes of 16./1023. NDC units.

Parameters of type REAL set in calls to entry CONOP3:

       CHL         This  parameter  determines  how  the high and low contour values are set.  The default is to
                   compute the high and low values from the input data.

       CIL         This parameter determines how the contour increment is set.  The default is to calculate  the
                   increment based on the range of the input data.

       CON         This parameter determines how the contour levels are set.  The default is to have the program
                   compute the contour values and the number of contour levels.

       DBP         This parameter determines how the dash pattern break point (BP) is set.  The default is BP=0.
                   (Does not apply to entry CONRAQ.)

       SDC         The  parameter to determine how to scale the data on the contours.  The default scaling is 1.
                   (Does not apply to entry CONRAQ.)

       SLD         This parameter allows for the entry of a bounding polygon (shield).  Only contours within the
                   shield are drawn.  The default is no shield.  (Does not apply to entry CONRAQ.)

       TEN         The parameter to determine the tension factor applied  when  smoothing  contour  lines.   The
                   default value is 2.5.  (Does not apply to entry CONRAQ.)

Parameters of type CHARACTER set in calls to entry CONOP4:

       DAS         This  parameter determines which contours are represented by dashed lines.  The default is to
                   draw all contours as solid lines.  (Does not apply to entry CONRAQ.)

       FMT         A parameter which specifies a format for output of the data values.  If FMT=OFF, the  default
                   values  of  the  format, the number of characters in the format, and the length of the output
                   field described in the format, are (G10.3), 7, and 10, respectively.

       TLE         The parameter to place a title at the top of the plot.  The default value is no title.

SEE ALSO

       Online: conran_family, conran, conraq, conras, conop1, conop2, conop3, conop4, conpack, conpack_params

       Hardcopy: NCAR Graphics Contouring and Mapping Tutorial; NCAR Graphics Fundamentals, UNIX Version; User's
       Guide for NCAR GKS-0A Graphics

COPYRIGHT

       Copyright (C) 1987-2009
       University Corporation for Atmospheric Research
       The use of this Software is governed by a License Agreement.

UNIX                                               March 1993                       Conran_family_params(3NCARG)