Provided by: linuxptp_4.0-1ubuntu1_amd64 bug

NAME

       phc2sys - synchronize two or more clocks

SYNOPSIS

       phc2sys -a [ -r ] [ -r ] [ -f config-file ] [ options ] [ long-options ]
       phc2sys [ -f config-file ] [ -d pps-device ] [ -s device ] [ -c device ] [ -O offset ] [ -w ] [ options ]
       [ long-options ] ...

DESCRIPTION

       phc2sys  is  a  program  which  synchronizes  two  or more clocks in the system. Typically, it is used to
       synchronize the system clock to a PTP hardware clock (PHC), which itself is synchronized by the  ptp4l(8)
       program.

       With the -a option, the clocks to synchronize are fetched from the running ptp4l daemon and the direction
       of synchronization automatically follows changes of the PTP port states.

       Manual  configuration  is  also  possible. When using manual configuration, two synchronization modes are
       supported, one uses a pulse per second (PPS) signal provided by the source clock and the other mode reads
       time from the source clock directly. Some clocks  can  be  used  in  both  modes,  the  mode  which  will
       synchronize the time sink with better accuracy depends on hardware and driver implementation.

OPTIONS

       -a     Read the clocks to synchronize from running ptp4l and follow changes in the port states, adjusting
              the   synchronization   direction   automatically.   The  system  clock  (CLOCK_REALTIME)  is  not
              synchronized, unless the -r option is also specified.

       -r     Only valid together with the -a option. Instructs phc2sys to also  synchronize  the  system  clock
              (CLOCK_REALTIME). By default, the system clock is not considered as a possible time source. If you
              want the system clock to be eligible to become a time source, specify the -r option twice.

       -f config
              Read configuration from the specified file. No configuration file is read by default.

       -d pps-device
              Specify  the  PPS  device  of  the  source  clock  (e.g.  /dev/pps0).  With  this  option  the PPS
              synchronization mode is used instead of the direct mode.  The matching PHC must be specified using
              the -s command line option.  This option can be used only with the system clock as the time  sink.
              Not compatible with the -a option.

       -s device
              Specify  the  source  clock  by  device (e.g. /dev/ptp0) or interface (e.g. eth0) or by name (e.g.
              CLOCK_REALTIME for the system clock). When this option is used together with the  -d  option,  the
              source  clock is used only to correct the offset by whole number of seconds, which cannot be fixed
              with PPS alone. Not compatible with the -a option. This option does not support  bonded  interface
              (e.g. bond0, team0). If ptp4l has a port on an active-backup bond or team interface, the -a option
              can be used to track the active interface.

       -i interface
              Performs  the  exact  same function as -s for compatibility reasons. Previously enabled specifying
              source clock by network interface. However, this can now be done using -s and this  option  is  no
              longer necessary. As such it has been deprecated, and should no longer be used.

       -c device
              Specify the time sink by device (e.g. /dev/ptp1) or interface (e.g. eth1) or by  name. The default
              is  CLOCK_REALTIME (the system clock). Not compatible with the -a option. This option may be given
              up to 128 times.

       -E servo
              Specify which clock servo should be used. Valid values are pi for a PI controller, linreg  for  an
              adaptive  controller  using  linear  regression,  and ntpshm and refclock_sock for the NTP SHM and
              chrony SOCK reference clocks respectively to allow another process to synchronize the local clock.
              The default is pi.

       -P kp  Specify the proportional constant of the PI controller. The default is 0.7.

       -I ki  Specify the integral constant of the PI controller. The default is 0.3.

       -S step
              Specify the step threshold of the servo. It is the maximum  offset  that  the  servo  corrects  by
              changing  the  clock  frequency  instead  of  stepping  the  clock.  The clock is stepped on start
              regardless of the option if the offset is larger than 20 microseconds (unless  the  -F  option  is
              used).  It's specified in seconds. The value of 0.0 disables stepping after the start. The default
              is 0.0.

       -F step
              Specify the step threshold applied only on the first update. It is  the  maximum  offset  that  is
              corrected  by  changing  the clock frequency. It's specified in seconds. The value of 0.0 disables
              stepping on start. The default is 0.00002 (20 microseconds).

       -R update-rate
              Specify the time sink update rate when running in the direct synchronization mode. The default  is
              1 per second.

       -N phc-num
              Specify  the  number  of  source  clock readings used for each time sink update.  Only the fastest
              reading is used to update the clock.  This is useful to minimize the error caused by random delays
              in scheduling and bus utilization.  The default is 5.

       -O offset
              Specify the offset between the sink and source times  in  seconds.  Not  compatible  with  the  -a
              option.  See TIME SCALE USAGE below.

       -L freq-limit
              The  maximum  allowed frequency offset between uncorrected clock and the system monotonic clock in
              parts per billion (ppb). This is used as a sanity check of the synchronized clock. When  a  larger
              offset  is measured, a warning message will be printed and the servo will be reset. When set to 0,
              the sanity check is disabled. The default is 200000000 (20%).

       -M segment
              The number of the SHM segment used by ntpshm servo.  The default is 0.

       -u summary-updates
              Specify the number of clock updates included in summary statistics. The statistics include  offset
              root mean square (RMS), maximum absolute offset, frequency offset mean and standard deviation, and
              mean  of  the  delay in clock readings and standard deviation. The units are nanoseconds and parts
              per billion (ppb). If zero, the individual samples are printed  instead  of  the  statistics.  The
              messages are printed at the LOG_INFO level.  The default is 0 (disabled).

       -w     Wait  until  ptp4l  is in a synchronized state. If the -O option is not used, also keep the offset
              between the sink and source times updated according to the currentUtcOffset  value  obtained  from
              ptp4l and the direction of the clock synchronization. Not compatible with the -a option.

       -n domain-number
              Specify the domain number used by ptp4l. The default is 0.

       -x     When  a  leap second is announced, don't apply it in the kernel by stepping the clock, but let the
              servo correct the one-second offset slowly by changing the clock frequency (unless the  -S  option
              is used).

       -z uds-address
              Specifies the address of the server's UNIX domain socket.  The default is /var/run/ptp4l.

       -l print-level
              Set the maximum syslog level of messages which should be printed or sent to the system logger. The
              default is 6 (LOG_INFO).

       -t message-tag
              Specify  the  tag which is added to all messages printed to the standard output or system log. The
              default is an empty string.

       -m     Print messages to the standard output.

       -q     Don't send messages to the system logger.

       -h     Display a help message.

       -v     Prints the software version and exits.

LONG OPTIONS

       Each and every configuration file option (see below in section FILE OPTIONS) may also appear as a  "long"
       style  command line argument.  For example, the transportSpecific option may be set using either of these
       two forms:

              --transportSpecific 1   --transportSpecific=1

       Option values given on the command line override values in the global section of the  configuration  file
       (which, in turn overrides default values).

CONFIGURATION FILE

       The  configuration  file  is  divided  into sections. Each section starts with a line containing its name
       enclosed in brackets and it follows with settings.  Each  setting  is  placed  on  a  separate  line,  it
       contains  the  name of the option and the value separated by whitespace characters. Empty lines and lines
       starting with # are ignored.

       The global section (indicated as [global]) sets the program options. This is the only used option.

FILE OPTIONS

       clock_servo
              The servo which is used to synchronize the local clock. Valid values are "pi" for a PI controller,
              "linreg" for an adaptive controller using linear regression, "ntpshm" for the  NTP  SHM  reference
              clock  to  allow  another process to synchronize the local clock (the SHM segment number is set to
              the domain number), and "nullf" for a servo that always dials frequency offset zero  (for  use  in
              SyncE nodes). The default is "pi."  Same as option -E (see above).

       domainNumber
              Specify the domain number used by phc2sys. The default is 0. Same as option -n (see above).

       first_step_threshold
              Specify  the  step  threshold  applied  only on the first update. It is the maximum offset that is
              corrected by adjusting clock. It's specified in seconds. The value of  0.0  disables  stepping  on
              start. The default is 0.00002 (20 microseconds).  Same as option -F (see above).

       free-running
              Don't adjust the sink clock if enabled. The default is 0 (disabled).

       kernel_leap
              When  a  leap  second  is  announced,  let  the  kernel  apply it by stepping the clock instead of
              correcting the one-second offset with servo, which would correct the one-second offset  slowly  by
              changing  the  clock  frequency (unless the step_threshold option is set to correct such offset by
              stepping). Relevant only with software time stamping. The default is 1 (enabled). Same  as  option
              -x (see above).

       logging_level
              The  maximum logging level of messages which should be printed.  The default is 6 (LOG_INFO). Same
              as option -l (see above).

       message_tag
              The tag which is added to all messages printed to the standard output or system log.  The  default
              is  an  empty  string  (which  cannot  be  set in the configuration file as the option requires an
              argument).  Same as option -t (see above).

       ntpshm_segment
              The number of the SHM segment used by ntpshm servo.  The default is 0.  Same  as  option  -M  (see
              above).

       pi_integral_const
              Specifies the integral constant of the PI controller.  Same as option -I (see above).

       pi_proportional_const
              Specifies the proportional constant of the PI controller.  Same as option -P (see above).

       refclock_sock_address
              The  address  of  the  UNIX  domain  socket to be used by the refclock_sock servo.  The default is
              /var/run/refclock.ptp.sock.

       sanity_freq_limit
              The maximum allowed frequency offset between uncorrected clock and the system monotonic  clock  in
              parts  per  billion (ppb). This is used as a sanity check of the synchronized clock. When a larger
              offset is measured, a warning message will be printed and the servo will be reset. When set to  0,
              the sanity check is disabled. The default is 200000000 (20%).  Same as option -L (see above).

       step_threshold
              Specifies  the  step  threshold  of the servo. It is the maximum offset that the servo corrects by
              changing the clock frequency (phase when using nullf servo) instead of  stepping  the  clock.  The
              clock  is  stepped  on start regardless of the option if the offset is larger than 20 microseconds
              (unless the -F option is used). It's specified in seconds. The  value  of  0.0  disables  stepping
              after the start. The default is 0.0.  Same as option -S (see above).

       transportSpecific
              The transport specific field. Must be in the range 0 to 255.  The default is 0.

       uds_address
              Specifies  the  address  of  the server's UNIX domain socket. The default is /var/run/ptp4 Same as
              option -z (see above).

       use_syslog
              Print messages to the system log if enabled.  The default is 1 (enabled).  Related  to  option  -q
              (see above).

       verbose
              Print messages to the standard output if enabled.  The default is 0 (disabled).  Related to option
              -m (see above).

TIME SCALE USAGE

       Ptp4l  uses  either  PTP  time  scale  or UTC (Coordinated Universal Time) time scale.  PTP time scale is
       continuous and shifted against UTC by a few tens of seconds  as  PTP  time  scale  does  not  apply  leap
       seconds.

       In  hardware  time  stamping  mode, ptp4l announces use of PTP time scale and PHC is used for the stamps.
       That means PHC must follow PTP time scale while system clock follows UTC.  Time offset between these  two
       is maintained by phc2sys.

       Phc2sys  acquires  the  offset  value  either by reading it from ptp4l when -a or -w is in effect or from
       command line when -O is supplied.  Failure to maintain the correct offset can result in the local  system
       clock  being  offset  some whole number of seconds from the domain server's clock when in client mode, or
       incorect PTP time announced to the network in case the host is the domain server.

EXAMPLES

       Synchronize time automatically according to the current ptp4l state, synchronizing the  system  clock  to
       the remote server.

              phc2sys -a -r

       Same  as above, but when the host becomes the domain server, synchronize time in the domain to its system
       clock.

              phc2sys -a -rr

       Same as above, in an IEEE 802.1AS domain.

              phc2sys -a -rr --transportSpecific=1

       The host is a domain server, PTP clock is synchronized to system clock and the time  offset  is  obtained
       from  ptp4l.   Phc2sys  waits for ptp4l to get at least one port in server or client mode before starting
       the synchronization.

              phc2sys -c /dev/ptp0 -s CLOCK_REALTIME -w

       Same as above, time offset is provided on command line and phc2sys does not wait for ptp4l.

              phc2sys -c /dev/ptp0 -s CLOCK_REALTIME -O 37

       The host is in client mode, system clock is synchronized from PTP clock, phc2sys waits for ptp4l and  the
       offset is set automatically.

              phc2sys -s /dev/ptp0 -w

       Same  as  above,  PTP clock id is read from the network interface, the offset is provided on command line
       phc2sys does not wait.

              phc2sys -s eth0 -O -37

WARNING

       Be cautious when the same configuration file is used for both ptp4l and  phc2sys.   Keep  in  mind,  that
       values  specified  in  the  configuration  file  take  precedence over their default values. If a certain
       option, which is common to ptp4l and phc2sys, is specified to a non-default value  in  the  configuration
       file  (p.e.,  for ptp4l), then this non-default value applies also for phc2sys. This might be not what is
       expected.

       It is recommended to use seperate configuration files for  ptp4l  and  phc2sys  in  order  to  avoid  any
       unexpected behavior.

SEE ALSO

       ptp4l(8)

linuxptp                                          February 2023                                       PHC2SYS(8)