Provided by: cpl-plugin-muse-doc_2.8.7+dfsg-3_all bug

NAME

       muse_astrometry - Compute an astrometric solution.

SYNOPSIS

       esorex muse_astrometry [OPTIONS] FILE.sof

DESCRIPTION

       Merge  pixel  tables  from  all  IFUs,  apply  correction  for  differential atmospheric refraction (when
       necessary), optionally apply flux calibration and telluric correction (if the necessary  input  data  was
       given),  and  resample  the data from all exposures into a datacube. Use the cube to detect objects which
       are then matched to their reference positions from which a  two-dimensional  WCS  solution  is  computed.
       There are two pattern matching algorithm implemented, which can be selected by chosing a positive or zero
       value  of  faccuracy.  In  the  first method (with a positive value of faccuracy), start using the search
       radius, and iteratively decrease it, until no duplicate detections are identified  any  more.  Similarly,
       iterate  the  data  accuracy  (decrease  it  downwards from the mean positioning error) until matches are
       found. Remove the remaining unidentified objects. The second method (when  faccuracy  is  set  to  zero),
       iterates  through  all  quadruples  in  both  the  detected  objects  and  the  catalogue, calculates the
       transformation and checks whether more than 80% of the  detections  match  a  catalog  entry  within  the
       radius.  The  main  output  is  the  ASTROMETRY_WCS file which is a bare FITS header containing the world
       coordinate solution. The  secondary  product  is  DATACUBE_ASTROMETRY,  it  is  not  needed  for  further
       processing  but  can  be  used for verification and debugging. It contains the reconstructed cube and two
       images created from it in further FITS extensions: a white-light image and the special image created from
       the central planes of the cube used to detect and centroid the stars (as well as its variance).

OPTIONS

       --centroid <str>
              Centroiding method to use for objects in the field of view. "gaussian" and "moffat" use 2D fits to
              derive the centroid, "box" is a simple centroid in a square box.  (str;  default:  ´moffat´).  The
              full  name  of  this  option  for  the  EsoRex configuration file is muse.muse_astrometry.centroid
              [default = moffat].

       --detsigma <float>
              Source detection sigma level to use. If this is negative, values between its absolute and 1.0  are
              tested  with  a stepsize of 0.1, to find an optimal solution. (float; default: 1.5). The full name
              of this option for the EsoRex configuration file is muse.muse_astrometry.detsigma [default = 1.5].

       --radius <float>
              Initial radius in pixels for pattern matching identification in  the  astrometric  field.  (float;
              default:   3.0).   The   full   name   of  this  option  for  the  EsoRex  configuration  file  is
              muse.muse_astrometry.radius [default = 3.0].

       --faccuracy <float>
              Factor of initial accuracy relative to mean positional accuracy of the measured positions  to  use
              for  pattern  matching.  If this is set to zero, use the quadruples based method. (float; default:
              0.0).   The   full   name   of   this   option   for   the   EsoRex    configuration    file    is
              muse.muse_astrometry.faccuracy [default = 0.0].

       --niter <int>
              Number  of  iterations of the astrometric fit. (int; default: 2). The full name of this option for
              the EsoRex configuration file is muse.muse_astrometry.niter [default = 2].

       --rejsigma <float>
              Rejection sigma level of the astrometric fit. (float; default: 3.0). The full name of this  option
              for the EsoRex configuration file is muse.muse_astrometry.rejsigma [default = 3.0].

       --rotcenter <str>
              Center  of  rotation  of  the  instrument,  given  as two comma-separated floating point values in
              pixels. (str; default: ´-0.01,-1.20´). The full name of this option for the  EsoRex  configuration
              file is muse.muse_astrometry.rotcenter [default = -0.01,-1.20].

       --lambdamin <float>
              Cut off the data below this wavelength after loading the pixel table(s). (float; default: 4000.0).
              The  full  name of this option for the EsoRex configuration file is muse.muse_astrometry.lambdamin
              [default = 4000.0].

       --lambdamax <float>
              Cut off the data above  this  wavelength  after  loading  the  pixel  table(s).  (float;  default:
              10000.0).   The   full   name   of   this   option   for   the   EsoRex   configuration   file  is
              muse.muse_astrometry.lambdamax [default = 10000.0].

       --lambdaref <float>
              Reference wavelength used for correction of differential atmospheric refraction. The R-band  (peak
              wavelength ~7000 Angstrom) that is usually used for guiding, is close to the central wavelength of
              MUSE,  so  a  value of 7000.0 Angstrom should be used if nothing else is known.  A value less than
              zero switches DAR correction off. (float; default: 7000.0). The full name of this option  for  the
              EsoRex configuration file is muse.muse_astrometry.lambdaref [default = 7000.0].

       --darcheck <str>
              Carry out a check of the theoretical DAR correction using source centroiding. If "correct" it will
              also  apply an empirical correction.  (str; default: ´none´). The full name of this option for the
              EsoRex configuration file is muse.muse_astrometry.darcheck [default = none].

       Note that it is possible to create a configuration file containing these  options,  along  with  suitable
       default values. Please refer to the details provided by the 'esorex --help' command.

SEE ALSO

       The full documentation for the muse pipeline can be downloaded as a PDF file using the following URL:

              ftp://ftp.eso.org/pub/dfs/pipelines/muse/muse-pipeline-cookbook-2.8.7.pdf

       An    overview    over    the    existing    ESO    pipelines    can   be   found   on   the   web   page
       https://www.eso.org/sci/software/pipelines/.

       Basic documentation about the EsoRex program can be found at the esorex (1) man page.

       It  is  possible  to  call   the   pipelines   from   python   using   the   python-cpl   package.    See
       https://packages.python.org/python-cpl/index.html for further information.

       The  other recipes of the muse pipeline are muse_ampl(7), muse_bias(7), muse_create_sky(7), muse_dark(7),
       muse_exp_align(7), muse_exp_combine(7), muse_flat(7), muse_geometry(7),  muse_illum(7),  muse_lingain(7),
       muse_lsf(7),   muse_qi_mask(7),   muse_scibasic(7),   muse_scipost(7),  muse_scipost_apply_astrometry(7),
       muse_scipost_calibrate_flux(7),      muse_scipost_combine_pixtables(7),      muse_scipost_correct_dar(7),
       muse_scipost_correct_rv(7),               muse_scipost_make_cube(7),               muse_scipost_raman(7),
       muse_scipost_subtract_sky(7),  muse_scipost_subtract_sky_simple(7),  muse_standard(7),  muse_twilight(7),
       muse_wavecal(7)

VERSION

       muse_astrometry 2.8.7

AUTHOR

       Peter Weilbacher <https://support.eso.org>

BUG REPORTS

       Please  report  any  problems to https://support.eso.org. Alternatively, you may send a report to the ESO
       User Support Department <usd-help@eso.org>.

LICENSE

       This file is part of the MUSE Instrument Pipeline Copyright (C) 2005, 2019 European Southern Observatory

       This program is free software; you can redistribute it and/or modify  it  under  the  terms  of  the  GNU
       General  Public License as published by the Free Software Foundation; either version 2 of the License, or
       (at your option) any later version.

       This program is distributed in the hope that it will be useful, but WITHOUT ANY  WARRANTY;  without  even
       the  implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the GNU General Public
       License for more details.

       You should have received a copy of the GNU General Public License along with this program; if not,  write
       to the Free Software Foundation, Inc., 51 Franklin St, Fifth Floor, Boston, MA  02111-1307  USA

muse_astrometry                                       2.8.7                                   MUSE_ASTROMETRY(7)